Optimizing the TLD-100 readout system for various radiotherapy beam doses using the Taguchi methodology.

@article{Chen2010OptimizingTT,
  title={Optimizing the TLD-100 readout system for various radiotherapy beam doses using the Taguchi methodology.},
  author={Chien Yi Chen and Kuo Chi Liu and Hsin Chen and Lung Kwang Pan},
  journal={Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine},
  year={2010},
  volume={68 3},
  pages={
          481-8
        }
}
The TLD-100 readout system was optimized for various radiotherapy beam doses using the Taguchi method. The radiotherapy beam was produced by a Varian 21EX linear accelerator (LINAC) at 6MV. The beam doses were 50, 100 and 150cGy, and the measured data in each group were averaged from three TLD-100 chips. A total of nine combinations of four parameters were arranged, in the manner suggested by Taguchi. The four parameters were defined as initial temperature, heating rate, preheat time and… CONTINUE READING