This paper presents a method for placing minimum number of phasor measurement units (PMUs) in a power system in order to locate any fault in the system. A procedure using integer linear programming framework is proposed. Modeling of zero injection bus is also considered. Simulation results for the IEEE 14 bus and 30 bus systems are reported. 

Figures and Tables from this paper.

Citations

Publications citing this paper.
SHOWING 1-10 OF 12 CITATIONS

Differential evolution based optimal PMU placement for fault observability of power system

  • 2013 Students Conference on Engineering and Systems (SCES)
  • 2013
VIEW 4 EXCERPTS
CITES METHODS & BACKGROUND
HIGHLY INFLUENCED

Feature-Selection based PMU Placement for Detection of Faults in Power Grids

  • 2018 28th International Telecommunication Networks and Applications Conference (ITNAC)
  • 2018
VIEW 1 EXCERPT
CITES BACKGROUND

PMU Optimal Placement using sensitivity analysis for power systems fault location

  • 2015 IEEE Electrical Power and Energy Conference (EPEC)
  • 2015
VIEW 1 EXCERPT
CITES METHODS

A multi-criteria optimal phasor measurement unit placement for multiple applications

  • 2013 IEEE Power & Energy Society General Meeting
  • 2013
VIEW 1 EXCERPT
CITES BACKGROUND

References

Publications referenced by this paper.
SHOWING 1-8 OF 8 REFERENCES

Phasor measurement unit placement techniques for complete and incomplete observability

  • IEEE Transactions on Power Delivery
  • 2005
VIEW 5 EXCERPTS
HIGHLY INFLUENTIAL

Determination of optimal pmu placement for fault-location observability

K. Mazlumi, H. A. Askarian, S. H. Sadegi, S. S. Geramian
  • Third international conference on Electric Utility Deregulation and Restructuring and Power Technologies, Apr. 6-9, 2008, pp. 1938-1942.
  • 2008
VIEW 2 EXCERPTS

Optimal PMU placement to ensure observability of power system

R. Sodhi, S. C. Srivastava
  • 2008

Optimal PMU placement to ensure observability of power system,”, presented at Fifteenth National Power Systems Conference, IIT Bombay,Dec

R. Sodhi, S. C. Srivastava
  • 2008
VIEW 2 EXCERPTS

Observability analysis and measurement placement for systems with PMUs

  • IEEE PES Power Systems Conference and Exposition, 2004.
  • 2004
VIEW 1 EXCERPT

Similar Papers