Tone detection thresholds for a 10-kHz tone in NMRI mice were determined in psychoacoustic experiments using both a constant-stimuli procedure and a two-down/one-up adaptive-tracking procedure in the same subjects and applying identical threshold criteria (70.7% response probability). Constant-stimuli thresholds were on average 24 dB lower than adaptive-tracking thresholds, and there was a trend indicating that constant-stimuli thresholds were less variable than adaptive-tracking thresholds… CONTINUE READING