On contact conditions in connectors to cause Common Mode radiation

@article{Hayashi2008OnCC,
  title={On contact conditions in connectors to cause Common Mode radiation},
  author={Y.-i. Hayashi and Yoshiki Kayano and Tatsuya Mizuki and Hideaki Sone and H. Inoue},
  journal={2008 IEEE International Symposium on Electromagnetic Compatibility},
  year={2008},
  pages={1-4}
}
When contact failure occurs in a connector in a coaxial HF signal transmission line, common mode (CM) radiation occurs on the line. We focus on contact conditions in a connector causing CM radiation. The experiments and the simulations verified that the CM radiation increases as contact resistance increases. While the CM current greatly depends on the… CONTINUE READING