Ocular Biometry and Cornea Biomechanics in Hypermetropic Anisometropia
@article{Aygt2014OcularBA, title={Ocular Biometry and Cornea Biomechanics in Hypermetropic Anisometropia}, author={E. D. Aygıt and Z. Alkın and B. Gokyigit and H{\"u}lya G{\"u}ngel and A. Demirok}, journal={T{\"u}rk Oftalmoloji Dergisi}, year={2014}, volume={44}, pages={23-26} }
Yazışma Adresi/Address for Correspondence: Dr. Ebru Demet Aygıt, Beyoğlu Göz Eğitim ve Araştırma Hastanesi, Göz Kliniği, İstanbul, Türkiye Tel.: +90 212 251 59 00 E-posta: ebrudemet@hotmail.com Geliş Tarihi/Received: 10.04.2013 Kabul Tarihi/Accepted: 19.08.2013 Amaç: Hipermetropik anizometropik gözlerde, ön kamara derinliği (ÖKD), kornea eğriliği (KE), merkezi kornea kalınlığı (MKK), horizontal kornea çapını içeren oküler biyometrik parametreleri ve Oküler Cevap Analizöru (OCA) ile ölçülen… CONTINUE READING
Topics from this paper
References
SHOWING 1-10 OF 14 REFERENCES
[Ocular biometry in children with hypermetropia: utility of the Lenstar LS 900 optical biometer (Haag-Streit(®))].
- Medicine
- Journal francais d'ophtalmologie
- 2011
- 2
- PDF
Evaluation of relationship of ocular parameters and depth of anisometropic amblyopia with the degree of anisometropia.
- Medicine
- Indian journal of ophthalmology
- 2006
- 22
Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children.
- Medicine
- Investigative ophthalmology & visual science
- 2008
- 96
Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.
- Medicine
- Investigative ophthalmology & visual science
- 2007
- 370
- PDF
A biometric investigation of ocular components in amblyopia
- Medicine
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
- 2008
- 21
Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer.
- Medicine
- American journal of ophthalmology
- 2006
- 156
Corneal biomechanics, refractive error, and axial length in Chinese primary school children.
- Medicine
- Investigative ophthalmology & visual science
- 2011
- 23
- PDF
Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
- Materials Science, Medicine
- Journal of cataract and refractive surgery
- 2005
- 612
Corneal biomechanical properties measured with the Ocular Response Analyser in a myopic population
- Chemistry, Medicine
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
- 2011
- 42