Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.

@article{Chertow1995NutritionalAW,
  title={Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.},
  author={Glenn M. Chertow and Edmund G. Lowrie and Douglas W. Wilmore and Jorge Fallas Gonz{\'a}lez and Nancy L. Lew and Jean Ling and Meryl S Leboff and Megan Gottlieb and Wen Wei Huang and Brian K. Zebrowski},
  journal={Journal of the American Society of Nephrology : JASN},
  year={1995},
  volume={6 1},
  pages={
          75-81
        }
}
Protein energy malnutrition is common among persons with ESRD and contributes substantially to morbidity and mortality. The usual methods of nutritional assessment, such as anthropometry, can be misleading because of altered tissue hydration. Bioelectrical impedance analysis (BIA) has been recommended by some as a practical nutritional assessment tool but has not been validated in patients with ESRD. Thirty-three stable patients on maintenance hemodialysis were evaluated in an ambulatory… CONTINUE READING

Similar Papers

Citations

Publications citing this paper.
SHOWING 1-10 OF 90 CITATIONS, ESTIMATED 56% COVERAGE

Bioimpedance spectroscopy for the estimation of fat-free mass in end-stage renal disease.

  • e-SPEN, the European e-journal of clinical nutrition and metabolism
  • 2011
VIEW 4 EXCERPTS
CITES RESULTS, METHODS & BACKGROUND
HIGHLY INFLUENCED

Analytic assessment of the various bioimpedance methods used to estimate body water.

  • Journal of applied physiology
  • 1998
VIEW 20 EXCERPTS
CITES BACKGROUND & METHODS
HIGHLY INFLUENCED

Body composition and cardiovascular risk factors in pretransplant hemodialysis patients.

  • Clinical nutrition
  • 2004
VIEW 3 EXCERPTS
CITES RESULTS & METHODS
HIGHLY INFLUENCED

FILTER CITATIONS BY YEAR

1997
2018

CITATION STATISTICS

  • 7 Highly Influenced Citations

  • Averaged 6 Citations per year from 2017 through 2019

References

Publications referenced by this paper.
SHOWING 1-10 OF 45 REFERENCES

Dawson - Hughes B , Heymsfield SB : Use of dual - energy x - ray absorptiometry in body composition studies : not yet a “ gold standard ”

R Roubenoff, JJ Kehayias
  • Am J Chin Nutr
  • 1993

Prealbumln and hipoprotein ( a ) in hemodialysis : Relationships with patient and vascular access survival

P Goidwasser, MA Michel, J Collier
  • Am J Kidney Dis
  • 1993

The impact of hydration status on the assessment of lean body mass by bioelectrical impedance in dialysis patients

CW deFitjer, MM deFltjer, LP Oe, AJ Donker, PM deVries
  • Adv Peritoneal Dial
  • 1993

Total body nitrogen by neutron activation in maintenance dialysis.

  • American journal of kidney diseases : the official journal of the National Kidney Foundation
  • 1993

Valid - ity of dual - energy x - ray absorptlometry ( DEXA ) and single frequency bioelectrical impedance analysis ( BIA ) in chronic hemodialysis patients ( Abstractl

DI Charney, JK Leypoldt, GM Chan, AK Cheung
  • J Am Soc Nephrol
  • 1993