Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft.

@article{Piazza1993NonanastomoticPO,
  title={Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft.},
  author={Duane Piazza and F. Michael Ameli and Herbert P. von Schroeder and Alan G Lossing},
  journal={Journal of vascular surgery},
  year={1993},
  volume={17 4},
  pages={
          777-9
        }
}
A case of nonanastomotic pseudoaneurysm of a unilateral axillofemoral bypass graft is reported. The graft material used in this particular instance was an 8 mm, reinforced, thin-walled, fluorinated ethylene-propylene-ringed, expanded polytetrafluoroethylene (ePTFE). The pseudoaneurysm occurred 1 year after insertion of the graft and was not associated with any direct trauma. It manifested with a painful tender mass at the top of the body of the axillofemoral bypass graft at the level of the… CONTINUE READING