Neuromonitoring in defibrillation threshold testing. A comparison between EEG, near-infrared spectroscopy and jugular bulb oximetry.

@article{Vries1997NeuromonitoringID,
  title={Neuromonitoring in defibrillation threshold testing. A comparison between EEG, near-infrared spectroscopy and jugular bulb oximetry.},
  author={Jaap W. de Vries and Gerhard Visser and Patricia F. A. Bakker},
  journal={Journal of Clinical Monitoring},
  year={1997},
  volume={13},
  pages={303-307}
}
Objectives. The aim was to study the physiological effects of induced ventricular fibrillation and subsequent circulatory arrest for defibrillation threshold testing on the brain using the EEG, jugular bulb oxymetry and near-infrared spectroscopy. Methods. Thirteen patients undergoing surgery for implantable cardioverter-defibrillator implantation or replacement under general anesthesia were included. We continuously monitored the jugular bulb oxygen saturation (SjO2), regional oxygen… CONTINUE READING

Citations

Publications citing this paper.
Showing 1-9 of 9 extracted citations

The Phenomenology of the Self-Conscious Mind

Robert G. Mays, B. Sc
2008
View 2 Excerpts

References

Publications referenced by this paper.
Showing 1-10 of 17 references

The impact of repeated short episodes of circulatory arrest on cerebral function. Reassuring electroecephalographic (EEG) ¢ndings during de¢brillation threshold testing at de¢brillator implantation

EM Vriens, PFA Bakker, JW deVries, GH Wieneke, AC van.Hu¡elen
EEG Clin Neurophysiol • 1996

Jugular bulb oximetry; a new approach to intensive neuromanagement

C. De Deyne
Thesis , Ghent ( Belgium ) • 1995
View 2 Excerpts

Electroencephalography-monitoring during implantation of an automatic implantable cardioverter-de¢brillator. E¡ects of repetitive cerebral ischemia on cortex cerebral activity

C Spies, T Heil, T Neumann, S. Kramer
J CardiothoracVasc Anesth • 1994

Neuromonitoring to improve the safety of de¢brillation threshold testing

HL Edmonds, RA Rodriguez, I Singer, W Ittichaikulthol, A. Yli-Hankala
Stroke • 1994

Implantable Cardioverter De¢brillator: Evaluation of neurologic outcome and EEG changes during implantation

DC Adams, EJ Heyer, +4 authors MF. Berman
Anesthesiology • 1993

Similar Papers