Multi-domain design of inverter-side inductor for LCL filter with 50kW 60 kHz high power density converter

Abstract

The weight of the LCL filter is a major contributor of the total weight of a high power converter, especially the inverter-side inductor. The design of the inverter-side inductor requires multi-domain optimization in electromagnetic design, weight reduction, and thermal management with the objective of meeting power quality standards. In this paper, the… (More)

16 Figures and Tables

Topics

  • Presentations referencing similar topics