Microscale Laser-Induced Fluorescence Method for Non-Intrusive Temperature Measurement

@inproceedings{Chamarthy2016MicroscaleLF,
  title={Microscale Laser-Induced Fluorescence Method for Non-Intrusive Temperature Measurement},
  author={Pramod Chamarthy and Steven Wereley and Suresh V. Garimella},
  year={2016}
}
Ratiometric Laser Induced Fluorescence (LIF) Thermometry is applied for temperature measurements in a ‘T’ junction, using microscale visualization methods. R hodamine B (RhB) and Rhodamine 110 (Rh110) are used as the temperature-dependent and temperature-independent d ye, respectively. The temperature responses of the two dyes were carefully measured for… CONTINUE READING