Measurement of plasma oxalate in healthy subjects and in patients with chronic renal failure using immobilised oxalate oxidase.

@article{Kasidas1986MeasurementOP,
  title={Measurement of plasma oxalate in healthy subjects and in patients with chronic renal failure using immobilised oxalate oxidase.},
  author={G. P. Kasidas and Gordon A. Rose},
  journal={Clinica chimica acta; international journal of clinical chemistry},
  year={1986},
  volume={154 1},
  pages={49-58}
}
A continuous flow assay using immobilised oxalate oxidase was used to measure the level of oxalate in plasma ultrafiltrate obtained from healthy subjects and from patients with chronic renal failure. The levels of oxalate in plasma from normal subjects ranged from 1.3-3.1 mumol/l (mean 2.03; SD = 0.52) with females showing a higher (p less than 0.05) level (mean 2.25 mumol/l) than males (mean 1.87 mumol/l). The mean oxalate/creatinine clearance ratio in fourteen healthy subjects was greater… CONTINUE READING