Measurement of Longitudinal Electron Diffusion in Liquid Argon

@inproceedings{Li2016MeasurementOL,
  title={Measurement of Longitudinal Electron Diffusion in Liquid Argon},
  author={Yichen Li and Thomas Tsang and Craig Edward Thorn and Xin Qian and Milind Vaman Diwan and Jyoti Mandar Joshi and Steve H. Kettell and William I. Morse and T. Someswara Rao and James Stewart and Wei Tang and Brett Viren},
  year={2016}
}
We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. In the region between 100 and 350 V/cm, our results show a discrepancy with the previous measurement [1]. In the region between 350 and 2000 V/cm, our results represent the world’s best measurement. Over the entire measured electric field… CONTINUE READING