Magnetization transfer in human Achilles tendon assessed by a 3D ultrashort echo time sequence: quantitative examinations in healthy volunteers at 3T.

Abstract

PURPOSE Magnetization transfer contrast (MTC) imaging provides insight into interactions between free and bounded water. Newly developed ultrashort echo time (UTE) sequences implemented on whole-body magnetic resonance (MR) scanners allow MTC imaging in tissues with extremely fast signal decay such as tendons. The aim of this study was to develop a technique for the quantification of the MT effect in healthy Achilles tendons in-vivo at 3 Tesla. MATERIALS AND METHODS 16 normal tendons of volunteers with no history of tendinopathy were examined using a 3D-UTE sequence with a rectangular on-resonant excitation pulse and a Fermi-shaped off-resonant MT preparation pulse. The frequency of the MT pulse was varied from 1 to 5 kHz. MT effects were calculated in terms of the MT ratio (MTR) between measurements without and with MT preparation. Direct saturation effects of MT preparation on the signal intensity were evaluated using numerical simulation of Bloch equations. One patient with tendinopathy was examined to exemplarily show changes of MTR under pathologic conditions. RESULTS Calculation of MTR data was feasible in all examined tendons and showed a decrease from 0.53 ± 0.05 to 0.25 ± 0.03 (1 kHz to 5 kHz) for healthy volunteers. Evaluation of variation with gender and dominance of ankle revealed no significant differences (p > 0.05). In contrast, the patient with confirmed tendinopathy showed MTR values between 0.36 (1 kHz) and 0.19 (5 kHz). CONCLUSION MT effects in human Achilles tendons can be reliably assessed in-vivo using a 3D UTE sequence at 3 T. All healthy tendons showed similar MTR values (coefficient of variation 10.0 ± 1.2 %). The examined patient showed a clearly different MT effect revealing a changed microstructure in the case of tendinopathy.

DOI: 10.1055/s-0031-1281742

Statistics

0204060201220132014201520162017
Citations per Year

65 Citations

Semantic Scholar estimates that this publication has 65 citations based on the available data.

See our FAQ for additional information.

Cite this paper

@article{Syha2011MagnetizationTI, title={Magnetization transfer in human Achilles tendon assessed by a 3D ultrashort echo time sequence: quantitative examinations in healthy volunteers at 3T.}, author={Roland Syha and Petros Martirosian and Dominik Ketelsen and Ulrich Grosse and Claus D. Claussen and Fritz Schick and Fabian Springer}, journal={RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin}, year={2011}, volume={183 11}, pages={1043-50} }