Machine stator iron evaluation through the use of resonant circuits

Abstract

The resonant system described here has several advantages: Calculations are simple, wide flux control is provided and power loss is easy to supply and accurately measure. Safety during a test is improved, since the resonance condition will collapse if circuit failure occurs. The system may not be resonaqt if extensive iron shorts exist and, with lower bus… (More)

7 Figures and Tables

Cite this paper

@article{Timperley1986MachineSI, title={Machine stator iron evaluation through the use of resonant circuits}, author={James E. Timperley and A. F. Bristor}, journal={IEEE Transactions on Energy Conversion}, year={1986}, volume={EC-1}, pages={94-100} }