MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

@article{Zangos2004MRguidedTB,
  title={MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results},
  author={Stephan Zangos and Katrin Eichler and Kerstin Engelmann and Mukhtiar Ahmed and S. Dettmer and Christopher Herzog and Wasilios Pegios and Axel Wetter and Thomas Lehnert and Martin G. Mack and Thomas J. Vogl},
  journal={European Radiology},
  year={2004},
  volume={15},
  pages={174-182}
}
The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The… CONTINUE READING