Low voltage ride-through control for fixed speed wind generators under grid unbalanced fault

@article{Ren2012LowVR,
  title={Low voltage ride-through control for fixed speed wind generators under grid unbalanced fault},
  author={Jiajia Ren and Yinghong Hu and Yanchao Ji and Chuang Liu},
  journal={2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC)},
  year={2012},
  pages={686-689}
}
As the wind power penetration in the power system is increasing rapidly, new grid connection codes for wind turbines are established. Low voltage ride through (LVRT) ability of wind turbines is required in order to ensure the voltage stability of the power system and improve the stability of wind generators. The characteristics of the fixed speed wind generators are described, and a new topology based on TSC for fixed speed induction wind generator LVRT capability and its control principle are… CONTINUE READING

From This Paper

Figures, tables, and topics from this paper.

Citations

Publications citing this paper.
Showing 1-7 of 7 extracted citations

References

Publications referenced by this paper.
Showing 1-10 of 12 references

Overview of different wind generator systems and their comparisons

H. Li, Z. Chen
IET. Renewable Power Generation, vol. 2, no. 2, pp. 123-138, 2008. • 2008
View 1 Excerpt

Stability improvement of induction generator-based wind turbine systems

Z. Chen, Y. Hu, F. Blaabierg
IET. Renewable Power Generation, vol. 1, no. 7, pp. 81-93, 2007. • 2007
View 1 Excerpt

Control of a doubly fed induction generator in a wind turbine during grid fault ride-through

D.W.Xiang, R. Li, P. J. Tavner
IEEE Transactions on Energy Conversion, vol. 21, no. 3, pp. 652-662, 2006. • 2006
View 2 Excerpts

Wind power in power systems

A. Thomas
Wind Engineering, vol. 30, no. 5, pp. 447-449, 2006. • 2006
View 1 Excerpt

Characteristics of induction generators and power system stability

2005 International Conference on Electrical Machines and Systems • 2005
View 1 Excerpt

Ride through of wind turbines with doubly-fed induction generator during a voltage dip

J. Morren, H DeHaanSW
IEEE Transactions on Energy Conversion, vol. 20, no. 2, pp. 435-441, 2005. • 2005
View 1 Excerpt

Voltage dip ride-through control of directive-drive wind turbines

J. Morren, T GPierikJ, W HDeHaanS
IEEE 2004 39 International Universities Power Engineering Conference, 2004, PP. 455-452. • 2004
View 1 Excerpt

Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault

2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) • 2004
View 1 Excerpt

Similar Papers