Longitudinal measurements of myocardial creatine content in normal and creatine transporter over-expressing mouse hearts using single voxel H-MRS in vivo

Abstract

D. Phillips, M. ten Hove, J. Wallis, S. Neubauer, J. E. Schneider Cardiovascular Medicine, University of Oxford, Oxford, Oxon, United Kingdom Introduction: Creatine (phosphorylated and unphosphorylated) plays a key role in the energy metabolism of the heart. To investigate the hypothesis that cardiac high-energy phosphate metabolism contributes to contractile dysfunction in heart failure, a transgenic mouse model that over-expresses the creatine transporter in the heart was created as a means to increase the myocardial creatine content (1). These animals show supra-normal, but variable creatine levels (65–240 nmol/mgPr compared to 58–74 nmol/mgPr in normal hearts) (1). The aim of this study was to investigate whether single voxel H-MRS can be used to non-invasively stratify the animals according to their creatine levels and to follow to them longitudinally. Methods: Female wild type (WT, n=7) and creatine transporter overexpressing (CrT, n=6) mice were subjected to cardiac H-MRS in vivo at the age of 6 weeks, 4 months and 8 months, respectively. After inducing anesthesia in an anesthetic chamber using 4 % isoflurane in 100 % oxygen, animals were positioned supine in a purpose-built animal holder for positioning mice vertically, and maintained at 1.5-2 % isoflurane in 1 l/min oxygen flow throughout the MR experiments. Spectroscopic experiments were carried out on an 11.7 T (500 MHz) MR system comprising a vertical magnet (bore size 123 mm – Magnex Scientific, Oxon, UK), a Bruker Avance console (Bruker Medical, Ettlingen, Germany) and a shielded gradient system (548 mT/m, 160 μs rise time) (Magnex Scientific, Oxon, UK). Quadrature driven birdcage coils with inner diameters of 28 mm and 40 mm (Rapid Biomedical, Würzburg, Germany) were used to transmit and receive the NMR-signals. Cardiac triggered and respiratory gated (with steady state maintenance (2)), water suppressed and unsuppressed cardiac spectra from a 2 μl voxel positioned in the interventricular septum were acquired in diastole using a PRESS sequence (TE = 9 ms, TR ≈ 2 s, NAE=256, repeated twice). All spectra were quantitatively analyzed using the time domain fitting software jMRUI (3) and the creatine signal referenced to the unsuppressed water signal. Results: Figure 1 and 2 show H-MR spectra obtained from a 2 μl voxel, placed in the interventricular septum of a WT and a CrT mouse heart, respectively. The arrow indicates the supra-normal creatine level (CH3-resonance of creatine at 3 ppm). H-MRS was successful in 71 out of 78 cases (91%). Figure 3 shows the overall mean relative creatine content for all 13 animals individually and the error bars encode the corresponding standard deviation. The CrT (filled symbols) had significantly higher relative creatine contents than the WT (open symbols; P<0.001 at all time points). The relative creatine content was at 6 weeks: 2.7 ± 0.9/8 ± 1, at 4 months: 3.0 ± 0.6/7 ± 1, and at 8 months: 3 ± 1/6 ± 2 (Mean ± SD, WT/CrT), respectively.

Extracted Key Phrases

1 Figure or Table

Cite this paper

@inproceedings{Phillips2005LongitudinalMO, title={Longitudinal measurements of myocardial creatine content in normal and creatine transporter over-expressing mouse hearts using single voxel H-MRS in vivo}, author={David G. Phillips and Michiel ten Hove and Jonathan P. Wallis and Stefan Neubauer and Jurgen E. Schneider}, year={2005} }