Long volume during high frequency oscillation.

@article{Bryan1986LongVD,
  title={Long volume during high frequency oscillation.},
  author={A. Charles Bryan and Arthur S Slutsky},
  journal={The American review of respiratory disease},
  year={1986},
  volume={133 5},
  pages={928-30}
}
Previous investigators have reported alarming gas trapping during high frequency oscillation. We have assessed trapping by measuring the difference between occlusion pressure (alveolar pressure) and measured maximal mean airway circuit pressure. Under normal operating conditions, we were unable to demonstrate trapping in normal or lung-lavaged rabbits at 15 or at 25 Hz, or in infants with infant respiratory distress syndrome, but we could produce trapping by operating at unusually low mean… CONTINUE READING

From This Paper

Topics from this paper.
18 Citations
0 References
Similar Papers

Citations

Publications citing this paper.
Showing 1-10 of 18 extracted citations

Similar Papers

Loading similar papers…