Logic circuit analysis and TEM inspection of IDDQ logic leakage

Abstract

The decreasing of technology node has made process of failure analysis become difficult. This paper outlines electrical fault localization method on IDDQ logic leakage failure. Upon fault localization, a complete analysis through TEM was performed for identification and further understanding of the failure mechanism eventually led to root cause finding. 