Load fatigue performance of a single-tooth implant abutment system: effect of diameter.

@article{Quek2006LoadFP,
  title={Load fatigue performance of a single-tooth implant abutment system: effect of diameter.},
  author={Christopher E Quek and Keson Beng-Choon Tan and Jack Ivan Nicholls},
  journal={The International journal of oral & maxillofacial implants},
  year={2006},
  volume={21 6},
  pages={
          929-36
        }
}
PURPOSE This study investigated the load fatigue performance of narrow-, regular-, and wide-diameter CeraOne (Nobel Biocare) single-tooth implants and abutments. MATERIALS AND METHODS Five samples of each implant-abutment combination in 3 different widths were tested at 3 applied screw torque levels (recommended torque, recommended torque +20%, and recommended torque -20%). A rotational load fatigue machine was used to apply a 21-N load, at an angle of 45 degrees to the long axis of the… CONTINUE READING

Citations

Publications citing this paper.
SHOWING 1-10 OF 53 CITATIONS, ESTIMATED 42% COVERAGE

Clinical and radiographic evaluation of early loaded narrow diameter implants - 1-year follow-up.

  • Clinical oral implants research
  • 2011
VIEW 2 EXCERPTS
CITES BACKGROUND
HIGHLY INFLUENCED

Influence of length, diameter and position of the implant in its fracture incidence: A Systematic Review.

Marcelo Coelho Goiato, Agda Marobo Andreotti, +3 authors Lisiane Cristina Bannwart
  • 2019
VIEW 1 EXCERPT
CITES BACKGROUND

FILTER CITATIONS BY YEAR

2008
2019

CITATION STATISTICS

  • 4 Highly Influenced Citations

References

Publications referenced by this paper.
SHOWING 1-10 OF 40 REFERENCES