• Corpus ID: 10199682

Linear collider test facility: ATF2 final focus active stabilisation pertinence

@inproceedings{Bolzon2009LinearCT,
  title={Linear collider test facility: ATF2 final focus active stabilisation pertinence},
  author={B. Bolzon and A. Jeremie and Andrei Seryi and Ph. Bambade and Yves R{\'e}nier},
  year={2009}
}
Beam motion at the Interaction Point (IP) of ATF2 has to be less than 10nm relative to the instrumentation used for measurements. Due to ground motion (GM), the beam can pass off-axis through the quadrupoles of the beam line and hence be deflected. It was shown in previous studies that good spatial coherence of the GM over a few meters makes the relative motion of the Final Doublets (FD) small enough for the tolerance not to be exceeded. However, since the coherence drops rapidly with distance… 

Figures and Tables from this paper

No title
The Accelerator Test Facility 2 (ATF2) commissioning group aims to demonstrate the feasibility of the Beam Delivery System (BDS) of the next linear colliders (ILC and CLIC) as well as to define and
Detect ground motion effects on the trajectory at ATF2
The Accelerator Test Facility 2 (ATF2) commissioning group aims to demonstrate the feasibility of the Beam Delivery System (BDS) of the next linear colliders (ILC and CLIC) as well as to define and
Stabilization study at the sub-nanometer level at the interaction point of the future Compact Linear Collider
The Compact LInear Collider (CLIC) is currently under design at CERN (European Organization for Nuclear Research). It would create high-energy particle collisions between electrons and positrons, and
Detection of Ground Motion effects on the beam trajectory at ATF2
The ATF2 experiment is currently demonstrating the feasibility of the beam delivery system for the future linear collider. The orbit feedback is very critical to obtain the nanometer vertical beam
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN - ACCELERATORS AND TECHNOLOGY SECTOR
A slim highly eccentric elliptical Crab cavity with vertical deflection at 800 MHz, compatible to beam line distances everywhere in the LHC ring, was designed. It is a good fall-back solution in case

References

SHOWING 1-10 OF 13 REFERENCES
Linear Collider Final Doublet Considerations: ATF2 Vibration Measurements
At ATF2, to allow the Shintake Monitor located at the Interaction Point to measure the beam size with only 2% of error, vertical relative motion tolerance between SM (Shintake Monitor) and final
R&D STATUS OF ATF2 IP BEAM SIZE MONITOR (SHINTAKE MONITOR)
Shintake monitor[2] is a nanometer-scale electron beam size monitor. It probes a electron beam by an interference fringe pattern formed by split laser beams. Minimum measurable beam size by this
Influence of ground motion on the time evolution of beams in linear colliders.
  • Šerý, Napoly
  • Physics, Medicine
    Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics
  • 1996
GM measurements and modeling at ATF2 " , ATF2 software task team monthly meeting
  • GM measurements and modeling at ATF2 " , ATF2 software task team monthly meeting
  • 2009
GM measurements and modeling at ATF2”, ATF2 software task team monthly meeting, KEK
  • 2009
Usefulness of a stabilization for the final focus quadrupoles?
  • ATF2 software task team monthly meeting
  • 2009
Usefulness of a stabilization for the final focus quadrupoles?”, ATF2 software task team monthly meeting, KEK
  • 2009
Efficiency of an active isolation of magnets from the ground for CLIC and ATF2 projects
  • CLIC Stabilisation Meeting
  • 2008
CERN CLIC table performance – Pertinence in ATF2 context
  • 3 rd ATF2 Project Meeting, KEK
  • 2006
CERN CLIC table performance – Pertinence in ATF2 context”, 3 ATF2 Project Meeting, KEK
  • 2006
...
1