Leakage tests of the stainless steel vessels of the antineutrino detectors in the Daya Bay reactor neutrino experiment

@article{Chen2012LeakageTO,
  title={Leakage tests of the stainless steel vessels of the antineutrino detectors in the Daya Bay reactor neutrino experiment},
  author={Xiao-hong Chen and Xiaolan Luo and Y. Heng and L. Wang and Xiao Tang and Xiaoyan Ma and H. Zhuang and H. Band and J. Cherwinka and Q. Xiao and K. Heeger},
  journal={Science China Technological Sciences},
  year={2012},
  volume={56},
  pages={148-151}
}
The antineutrino detectors for the Daya Bay reactor neutrino experiment are liquid scintillator detectors designed to detect electron anti-neutrino via inverse beta interactions with high efficiency and low backgrounds. Since the antineutrino detector will be installed and immerged in water Cherenkov detector and will run for 3 to 5 years, water tightness is critical to the successful operation of the antineutrino detectors. A special seal technique was used for this purpose. Three leak… Expand
4 Citations
The Detector System of The Daya Bay Reactor Antineutrino Experiment
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\bar{\nu}_e$ oscillations over km-baselines.Expand
Application of an acrylic vessel supported by a stainless-steel truss for the JUNO central detector
After the success of the Daya Bay experiment, the Jiangmen Underground Neutrino Observatory (JUNO) was launched to measure neutrino-mass hierarchy and oscillation parameters and to study otherExpand
Detector control system for Daya Bay Reactor Neutrino Experiment
The Daya Bay Reactor Neutrino Experiment is to measure the smallest mixing angle θ13. The experiment contains three major experiment halls, Daya Bay near site, Linao near site and far site, and twoExpand
Aging behavior and lifetime prediction of PMMA under tensile stress and liquid scintillator conditions
Abstract The aging behaviors of PMMA in liquid scintillator at different temperatures of 30 °C, 40 °C, 50 °C and 55 °C under static tensile stress were experimentally investigated with dynamicExpand

References

SHOWING 1-3 OF 3 REFERENCES
A side-by-side comparison of Daya Bay antineutrino detectors
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle θ_(13) with a sensitivity better than 0.01 in the parameter sin^22θ_(13) at the 90% confidenceExpand
Observation of electron-antineutrino disappearance at Daya Bay.
The Daya Bay Reactor Neutrino Experiment has measured a nonzero value for the neutrino mixing angle θ(13) with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GWth reactors wereExpand
Mechanics of Fluids
Contents Preface to the eighth edition 1 Fundamental Concepts Problems 2 Fluid Statics Problems 3 The Principles Governing Fluids in Motion Problems 4 The Momentum Equation 5. Physical Similarity andExpand