          411-5
        }
}
The aim of the present study was to compare the mean bonding time, mean shear bond strength and mean survival time of stainless steel brackets with a micro-etched base bonded with a light-cure composite using a self-etching primer (SEP) or a conventional two-stage etch and prime system. Brackets were bonded to 30 premolars with each bonding system. The bonding time was recorded for each specimen using a stopwatch. After storage in a humidor at 37 degrees C for 24 hours, the shear debonding… 
Effects of self-etching primer on shear bond strength of orthodontic brackets at different debond times.
TLDR
Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method, and it is reliable to load the bracket 5 minutes after bonding usingSelf Etching Primer with the light-cure adhesive (Transbond XT).
Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study.
TLDR
A clinical trial using TPSEP as a conditioner would be useful as the time taken to remove the adhesive from the enamel surface may be reduced following debond.
Six and 12 months' evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trial.
TLDR
The mean clinical chair-side time required for bracket bonding and the mean bond failure rate at 6 and 12 months of stainless steel brackets with a micro-etched base bonded with a light-cured composite using a self-etching primer (SEP) or a two-stage etch and prime system were compared.
Laboratory evaluation of shear bond strength of three different bonding systems for orthodontic brackets
TLDR
Orthodontic brackets bonded to enamel surface using one-step bonding system (GC ortho connect) without primer was significantly higher than brackets bonded using conventional or self-etch systems.
Six-month bracket failure rate evaluation of a self-etching primer.
TLDR
The results of this in vivo, randomized, cross-mouth clinical trial demonstrated a high survival rate with Transbond Plus, indicating that SEP can be effectively used for bonding of orthodontic brackets.
Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system.
TLDR
This study compared the total bonding time and shear bond strength (SBS) of 2 bracket-bonding systems: an integrated system that incorporates a self-etching primer and precoated brackets and a conventional system in which the etchant and primer are applied separately and the adhesive applied to the bracket by the clinician.
Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.
TLDR
This long-term in vivo study showed that the combined use of SEP and the APC bracket system can be used effectively for bonding brackets after pumicing the enamel surfaces in clinical orthodontics.
An Investigation into the Use of a Single Component Self-etching Primer Adhesive System for Orthodontic Bonding: A Randomized Controlled Clinical Trial
TLDR
The study found that enamel pre-treatment with the Ideal 1 self-etching primer system prior to orthodontic bonding results in an unacceptably high bond failure rate when compared with conventional enamel acid etching.
The in vitro effect of repeated bonding on the shear bond strength with different enamel conditioning procedures.
TLDR
Evaluating the effect on shear bond strength, adhesive remnant, and enamel surface of repeated bonding of new brackets on the same tooth using different methods of enamel conditioning found TSEP and NRC produced bonds that were similar to acid etching.
Effect of clearfil protect bond and transbond plus self-etch primer on shear bond strength of orthodontic brackets
TLDR
The shear bond strength of clearfil protect bond and transbond plusSelf-etch primer was enough for bonding the orthodontic brackets and the mode of failure of bonded brackets with these two self-etch primers is safe for enamel.
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 26 REFERENCES
Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets.
  • S. Bishara, L. Vonwald, J. Laffoon, J. Warren
  • Medicine, Materials Science
    American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • 2001
TLDR
The present in vitro findings indicate that the use of a self-etch primer to bond orthodontic brackets to the enamel surface resulted in a significantly lower, but clinically acceptable, shear bond force.
Bond strength of a fluoride-releasing bracket adhesive
TLDR
The bond strength results obtained in the shear test recommend the new fluoridereleasing light-cured filling composite for its bonding and debonding qualities when used as a bracket adhesive to be used with orthophosphoric acid for etching.
A laboratory investigation to compare enamel preparation by sandblasting or acid etching prior to bracket bonding.
TLDR
Brackets bonded to etched enamel showed a mixed mode of bond failure whereas following sandblasting, failure was adhesive at the enamel/composite interface (P < 0.01); and weibull analysis showed that at a given stress the probability of failure was significantly greater for brackets bonded to sandblasted enamel.
Shear bond strength of composite, glass ionomer, and acidic primer adhesive systems.
  • S. Bishara, V. Gordan, L. Vonwald, J. Jakobsen
  • Medicine, Materials Science
    American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • 1999
An Ex Vivo Study to Investigate Bond Strengths of Different Tooth Types
TLDR
The validity of the long-held assumption that a high ex vivo bond strength is synonymous with low failure rates or enhanced clinical survival has been questioned, and doubt is cast over the applicability of this assumption when comparing ex vivo Bond strength with in vivo clinical bond failure rates.
Laboratory evaluation of a compomer and a resin-modified glass ionomer cement for orthodontic bonding.
TLDR
The compomer and the resin-modified glass ionomer adhesive appear to offer viable alternatives to the more commonly used resin adhesives for bracket bonding.
The inappropriateness of conventional orthodontic bond strength assessment protocols.
TLDR
A novel approach to study the fatigue life of materials is proposed to understand the processes occurring prior to bond failure and recommendations for future research are made to ensure scientific soundness and clinical applicability of data.
The Role of Sandblasting on the Retention of Metallic Brackets Applied with Glass Ionomer Cement
TLDR
Sandblasting of the bracket base was undertaken in half of the sample bonded with Ketac-Cem and produced a significant reduction in the probability of failure relative to the unsandblasted sample.
One-step etch/primer for bracket bonding.
A single step etch/primer that can be used for bonding orthodontic brackets with virtually any light polymerized resin-based composite bracket adhesive material that has been introduced. Clinical
...
1
2
3
...