• Corpus ID: 220280284

LabOSat as a versatile payload for small satellites: first 100days in LEO orbit

@article{Sanca2020LabOSatAA,
  title={LabOSat as a versatile payload for small satellites: first 100days in LEO orbit},
  author={Gabriel A. Sanca and Mariano Barella and Fernando Gomez Marlasca and G. Rodr'iguez and D. Martelliti and L.Patrone and Pablo Levy and F. Golmar},
  journal={arXiv: Instrumentation and Detectors},
  year={2020}
}
In this work the first results obtained by LabOSat-01 platform are presented. This platform was designed for testing custom devices on board of small satellites. Two LabOSat-01 type boards were launched and placed into Low Earth Orbit (LEO) on May 30, 2016. We present here an analysis of data collected by one of these boards during the first days of mission. Total Ionization Dose results are compared with data acquired by LabOSat-01`s predecessor board, MeMOSat-01, launched in 2014. 

Figures from this paper

YBCO-based non-volatile ReRAM tested in Low Earth Orbit

An YBCO-based test structure corresponding to the family of ReRAM devices associated with the valence change mechanism is presented. We have characterized its electrical response previous to its

Proton irradiation effects on metal-YBCO interfaces

References

SHOWING 1-10 OF 11 REFERENCES

LabOSat: Low cost measurement platform designed for hazardous environments

In this work the characteristics and performance of LabOSat platform to carry out experiments over electronic devices in aggressive environments are described. Configurable, portable, low weight and

Studying the Total Ionizing Dose and Displacement Damage Dose efiects for various orbital trajectories

Faculty of Science, Cairo University, Giza, Cairo, Egyptemail: aahady@yahoo.comAbstract. The impact of radiation efiects is growing more critical with the advent of newertechnologies in space. The

Radiation Test Results for Common CubeSat Microcontrollers and Microprocessors

SEL, SEU, and TID results are presented for microcontrollers and microprocessors of interest for small satellite systems such as the TI MSP430F1611, MSP430F1612 and MSP430FR5739, Microchip

Electrically Erasable Metal–Oxide–Semiconductor Dosimeters

Metal-oxide-semiconductor (MOS) dosimetry including the reset of the sensor device for its reuse (reutilization) is described. The method consists in restoring the shifted threshold voltage after

Stand alone MOS dosimetry system for high dose ionizing radiation

A Metal Oxide Semiconductor (MOS) dosimetry system prototype for measurement of high dose ionizing radiation is presented. The hardware design target is to implement the Bias Controlled Cycled

A Comparison of the Radiation Response of ${\rm TaO}_{\rm x}$ and ${\rm TiO}_2$ Memristors

The effects of radiation on memristors created using tantalum oxide and titanium oxide are compared. Both technologies show changes in resistance when exposed to 800 keV Ta ion irradiation at

Total ionizing dose effects in MOS oxides and devices

This paper reviews the basic physical mechanisms of the interactions of ionizing radiation with MOS oxides, including charge generation, transport, trapping and detrapping, and interface trap

Space radiation environment forecast for EGYPTSAT‐2 satellite

The space environment provides an assortment of hazards whose ill effects can range from degraded performance up to catastrophic loss of a spacecraft. The radiation environment is believed to be the

Satellogic

    A Comparison of the Radiation Response of TaOx and TiO2 Memristors

    • IEEE Transactions on Nuclear Science,