Iterative Off-Resonance and Signal Decay Estimation and Correction for Multi-Echo MRI

@article{Knopp2009IterativeOA,
  title={Iterative Off-Resonance and Signal Decay Estimation and Correction for Multi-Echo MRI},
  author={T. Knopp and H. Eggers and H. Dahnke and J{\"u}rgen Prestin and J. S{\'e}n{\'e}gas},
  journal={IEEE Transactions on Medical Imaging},
  year={2009},
  volume={28},
  pages={394-404}
}
  • T. Knopp, H. Eggers, +2 authors J. Sénégas
  • Published 2009
  • Computer Science, Medicine
  • IEEE Transactions on Medical Imaging
  • Signal dephasing due to field inhomogeneity and signal decay due to transverse relaxation lead to perturbations of the Fourier encoding commonly applied in magnetic resonance imaging. Hence, images acquired with long readouts suffer from artifacts such as blurring, distortion, and intensity variation. These artifacts can be removed in reconstruction, usually based on separately collected information in form of field and relaxation maps. In this work, a recently proposed gridding-based algorithm… CONTINUE READING
    Correction of gradient echo images for first and second order macroscopic signal dephasing using phase derivative mapping
    14
    Advances in real-time phase-contrast flow MRI and multi-echo radial FLASH
    3
    Imaging with referenceless distortion correction and flexible regions of interest using single-shot biaxial spatiotemporally encoded MRI
    13
    Calibration-Free B0 Correction of EPI Data Using Structured Low Rank Matrix Recovery
    8
    Development and Optimization of Methods for Accelerated Magnetic Resonance Imaging

    References

    Publications referenced by this paper.
    SHOWING 1-10 OF 28 REFERENCES
    Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
    339
    Dynamic field map estimation using a spiral-in/spiral-out acquisition.
    89
    Iterative B0 and T2 * Correction for Radial Multi-Gradient-Echo Imaging
    6
    Field Inhomogeneity Correction Based on Gridding Reconstruction for Magnetic Resonance Imaging
    37
    Multifrequency interpolation for fast off-resonance correction.
    147
    Iterative reconstruction of single-shot spiral MRI with off resonance
    40
    A homogeneity correction method for magnetic resonance imaging with time-varying gradients.
    232
    Reconstruction by weighted correlation for MRI with time-varying gradients.
    74
    Functional imaging by I0- and T2*-parameter mapping using multi-image EPI.
    139