Intraocular pressure and tear production in captive eland and fallow deer.

@article{Ofri2001IntraocularPA,
  title={Intraocular pressure and tear production in captive eland and fallow deer.},
  author={Ron Ofri and Harold Horowitz and Moshe Levison and Philip H Kass},
  journal={Journal of wildlife diseases},
  year={2001},
  volume={37 2},
  pages={387-90}
}
Applanation tonometry was used to estimate intraocular pressure (IOP) and Schirmer tear test (STT) I was used to estimate tear production in both eyes of 12 juvenile elands (Taurotragus oryx) and one eye each of 15 Asian fallow deer (Dama mesopotamica). Mean (+/- standard deviation) IOP was 14.6 +/- 4.0 mm Hg in the eland and 11.9 +/- 3.3 mm Hg in the deer. Mean tear production was 18.7 +/- 5.9 mm/min in the eland and 10.5 +/- 6.5 mm/min in the deer. The large variation in IOP between two… CONTINUE READING