Interprosthetic Fracture of Distal Femur Around Total Knee Replacement with Pre-Existing Dynamic Condylar Screw: 發生在股骨遠端,介乎於動力髖螺釘和全膝關節置換假體之間的骨折:病例報告

@inproceedings{Lau2016InterprostheticFO,
  title={Interprosthetic Fracture of Distal Femur Around Total Knee Replacement with Pre-Existing Dynamic Condylar Screw: 發生在股骨遠端,介乎於動力髖螺釘和全膝關節置換假體之間的骨折:病例報告},
  author={Chi Kin Lau and Hang Cheong Cheng and Hon Shuen Ho},
  year={2016}
}
Abstract Treatment of interprosthetic fracture of distal femur around total knee replacement is difficult. Pre-existing hip implants further increase the technical challenges. In this case report, we present an 85-year-old patient who suffered from a displaced distal femur fracture with a pre-existing dynamic condylar screw and total knee replacement. Internal fixation with distal femur locking plate and incorporation of the locking plate with the pre-existing dynamic condylar screw provided a… CONTINUE READING

Topics from this paper.