Interface contact profiles of a novel locking plate and its effect on fracture healing in goat.

@article{Wei2010InterfaceCP,
  title={Interface contact profiles of a novel locking plate and its effect on fracture healing in goat.},
  author={Da-cheng Wei and Yu-feng Zhao and Shu-xing Xing and Ai-Min Wang},
  journal={Chinese journal of traumatology = Zhonghua chuang shang za zhi},
  year={2010},
  volume={13 4},
  pages={
          240-3
        }
}
OBJECTIVE To evaluate the interface characteristics of the new-designed locking plate (LP) and limited contact-dynamic compression plate (LC-DCP) and compare the fracture healing between LP and LC-DCP in a goat tibia fracture model. METHODS Eight-hole LP and LC-DCP were applied to fix fresh goat tibiae in a reproducible manner. The average pressure, force and interface contact area were calculated using Fuji prescale pressure sensitive film interposed among the plate and the bone and image… CONTINUE READING