Intercomparison of magnetic flux density by means of field coil transfer standard

@article{Weyand2000IntercomparisonOM,
  title={Intercomparison of magnetic flux density by means of field coil transfer standard},
  author={Kurt Weyand},
  journal={Conference on Precision Electromagnetic Measurements. Conference Digest. CPEM 2000 (Cat. No.00CH37031)},
  year={2000},
  pages={246-}
}
  • Kurt Weyand
  • Published 2000 in
    Conference on Precision Electromagnetic…
The coil constant k/sub 0/-i.e. the quotient of magnetic flux density in the coil centre over the coil current-of a Garrett type field coil has been determined in units as maintained by various standard laboratories. Most of the laboratories have also measured the coil constant k(f) as function of frequency up to f=15 kHz.