Integra Bilayer Matrix Wound Dressing closure of large periorbital traumatic wound.

@article{Thinda2012IntegraBM,
  title={Integra Bilayer Matrix Wound Dressing closure of large periorbital traumatic wound.},
  author={Sumeer Thinda and Harry V Wright and Louise A. Mawn},
  journal={Archives of ophthalmology},
  year={2012},
  volume={130 2},
  pages={
          217-9
        }
}
  • Sumeer Thinda, Harry V Wright, Louise A. Mawn
  • Published in Archives of ophthalmology 2012
  • Medicine
  • We report the first use of the Integra Bilayer Matrix Wound Dressing (Integra LifeSciences Corp), a collagen sheet with glycosaminoglycans and a silicone layer, in an innovative reconstruction approach to devastating traumatic tissue loss in the periocular area. A 36-year-old woman was involved in a motor vehicle crash with a resultant large defect from the medial canthus to the temporal fossa and from the pretarsal skin to the brow. There was denudation of skin and soft tissue to the bone at… CONTINUE READING