Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible.
@article{Hermann2001InfluenceOT,
title={Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible.},
author={Joachim S. Hermann and John D. Schoolfield and Robert K. Schenk and Daniel Buser and David L. Cochran},
journal={Journal of periodontology},
year={2001},
volume={72 10},
pages={
1372-83
}
}BACKGROUND
Endosseous implants can be placed according to a non-submerged or submerged approach and in 1- or 2-piece configurations. Recently, it was shown that peri-implant crestal bone changes differ significantly under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of an interface (microgap) between the implant and abutment/restoration in 2-piece configurations. Several factors may influence the resultant level of the crestal bone…
Topics from this paper
429 Citations
Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: a radiographic study in the canine mandible.
- Medicine, Materials ScienceJournal of periodontology
- 2002
Crestal bone loss was an early manifestation of wound healing occurring after 1 month of implant placement and the size of the microgap at the implant-abutment interface had no significant effect upon crestal bone resorption, implying that implant configurations incorporating interfaces will be associated with biological changes regardless of interface size.
Influence of a machined collar on crestal bone changes around titanium implants: a histometric study in the canine mandible.
- MedicineJournal of periodontology
- 2011
Choosing a completely SLA-surfaced non-submerged implant can reduce the amount of peri-implant crestal bone loss and reduce the distance from the MG to the first bone-im implant contact around unloaded implants compared to implants with a machined collar.
Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs.
- MedicineJournal of clinical periodontology
- 2007
It was concluded that both CAM and CPS implants revealed crestal bone-level changes after 28 days of healing, and both groups revealed significantly increased mean IS-BC values at the buccal aspect of the alveolar bone.
Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements.
- MedicineThe International journal of oral & maxillofacial implants
- 2001
Standardized periapical radiography can evaluate crestal bone levels around implants clinically accurately in a high percentage of cases and may prove beneficial when trying to distinguish physiologic changes from pathologic changes or when Trying to determine causes and effects of bone changes around dental implants.
Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs.
- MedicineJournal of clinical periodontology
- 2009
It was concluded that bone remodelling was minimal in both groups and platform switching may not be of crucial importance for maintenance of the crestal bone level.
Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs.
- Medicine, Materials ScienceClinical oral implants research
- 2008
It is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths.
- MedicineJournal of periodontology
- 2005
The implant design with the shorter smooth coronal collar had no additional bone loss and may help to reduce the risk of an exposed metal implant margin in areas of esthetic concern.
A 16-year study of the microgap between 272 human titanium implants and their abutments.
- Medicine, Materials ScienceThe Journal of oral implantology
- 2005
In screw-retained abutments the microgap can be a critical factor for colonization of bacteria, whereas in cement-retains all the internal spaces were filled by cement.
Equicrestal and subcrestal dental implants: a histologic and histomorphometric evaluation of nine retrieved human implants.
- MedicineJournal of periodontology
- 2011
The present retrospective histologic study evaluated dental implants retrieved from human jaws that had been inserted in an equicrestal or subcrestal position and found preexisting and newly formed bone was found over the implant shoulder.
Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys.
- Medicine, BiologyJournal of periodontology
- 2003
The results confirm data published previously that if the microgap was moved coronally away from the alveolar crest, less bone loss would occur andIf the micro gap was moved apical to theAlveolars crest, greater amounts of bone resorption were present.
References
SHOWING 1-10 OF 29 REFERENCES
Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible.
- Medicine, Materials ScienceJournal of periodontology
- 2000
These findings, as evaluated by non-decalcified histology under unloaded conditions, demonstrate that crestal bone changes occur during the early phase of healing after implant placement, and are dependent on the surface characteristics of the implant and the presence/absence of an interface.
Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements.
- MedicineThe International journal of oral & maxillofacial implants
- 2001
Standardized periapical radiography can evaluate crestal bone levels around implants clinically accurately in a high percentage of cases and may prove beneficial when trying to distinguish physiologic changes from pathologic changes or when Trying to determine causes and effects of bone changes around dental implants.
Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible.
- MedicineJournal of periodontology
- 1997
The data suggest that a biologic width exists around unloaded and loaded nonsubmerged one-part titanium implants and that this is a physiologically formed and stable dimension as is found around teeth.
Biologic Width around one- and two-piece titanium implants.
- MedicineClinical oral implants research
- 2001
Findings, as evaluated by nondecalcified histology under unloaded conditions in the canine mandible, suggest that the gingival margin (GM) is located more coronally and Biologic Width (BW) dimensions are more similar to natural teeth around one-piece nonsubmerged implants compared to either two- piece nonsubMERged or two-piece submerged implants.
Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiographic results.
- Medicine, Materials ScienceClinical oral implants research
- 1996
It is suggested that SLA implants are superior to TPS implants as measured radiographically in oral bone under unloaded and loaded conditions.
The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog.
- Materials Science, MedicineClinical oral implants research
- 1996
It is suggested that correctly performed implant installation may ensure proper conditions for both and hard tissue healing, and that the geometry of the titanium implant seems to be of limited importance.
Initial healing in the dog of submerged versus non-submerged porous-coated endosseous dental implants.
- MedicineClinical oral implants research
- 1996
Histomorphometric analysis revealed bone-implant contact, as assessed by absolute bone contact (ABC) and contact length fraction (CLF), to be greater for the submerged design, suggesting that bone healing may be delayed with the non-submerged approach.
Biologic width around titanium implants. A physiologically formed and stable dimension over time.
- MedicineClinical oral implants research
- 2000
Data indicate that the Biologic Width is a physiologically formed and stable structure over time in the case of non-submerged, one-piece titanium implants as evaluated histometrically under unloaded and loaded conditions for up to 12 months.
Radiographical and histological characteristics of submerged and nonsubmerged titanium implants. An experimental study in the Labrador dog.
- Medicine, Materials ScienceClinical oral implants research
- 1996
This study demonstrates that, using a dog model, titanium dental implants ad modum Brånemark installed according to a 1-step or to a 2-step surgical procedure will obtain similar soft tissue adaptation and proper bone anchorage.
Peri-implant tissues at submerged and non-submerged titanium implants.
- Medicine, Materials ScienceJournal of clinical periodontology
- 1999
It was observed that the mucosa and bone tissue that formed at implants placed in a non-submerged or a submerged procedure had many features in common, and it is suggested that a non"-1-stage" installation technique may provide conditions for tissue integration that are similar to those obtained using a submerged (2-stage) approach.