Influence of KTP length on the performance intracavity frequency doubled diode-pumped Nd:YVO4 lasers

@article{Chen1998InfluenceOK,
  title={Influence of KTP length on the performance intracavity frequency doubled diode-pumped Nd:YVO4 lasers},
  author={Yf Chen},
  journal={IEEE Photonics Technology Letters},
  year={1998},
  volume={10},
  pages={669-671}
}
  • Yf Chen
  • Published in
    IEEE Photonics Technology…
    1998
  • Physics
  • We demonstrate an experimental study of the influence of potassium titanyl phosphate (KTP) length on the performance of intracavity frequency-doubled diode-pumped Nd:YVO/sub 4/ lasers operating in continuous-wave (CW) mode and passive Q-switch mode. Theoretical and experimental results show that the optimum KTP length for CW mode is determined by the nonlinear coupling and walkoff effect and the highest optical conversion efficiency in CW mode is nearly 30% with a 10-mm KTP. On the other hand… CONTINUE READING

    Create an AI-powered research feed to stay up to date with new papers like this posted to ArXiv

    Figures from this paper.

    Citations

    Publications citing this paper.
    SHOWING 1-2 OF 2 CITATIONS

    Single Frequency Green Laser with Birefringent Filter

    VIEW 1 EXCERPT
    CITES METHODS

    References

    Publications referenced by this paper.
    SHOWING 1-10 OF 11 REFERENCES

    Nakaii, “Singlelongitudinal-mode operation and second-harmonic generation of Nd:YVO4 microchip lasers,”Opt

    • T. Sasaki, T. Kojima, A. Yokotani, O. Oguri
    • Lett. ,
    • 1991
    VIEW 1 EXCERPT