Indication for the need of flexible and frequency specific mapping functions in cochlear implant speech processors

@article{Hoth2006IndicationFT,
  title={Indication for the need of flexible and frequency specific mapping functions in cochlear implant speech processors},
  author={S. Hoth},
  journal={European Archives of Oto-Rhino-Laryngology},
  year={2006},
  volume={264},
  pages={129-138}
}
  • S. Hoth
  • Published 2006
  • Medicine
  • European Archives of Oto-Rhino-Laryngology
Categorical loudness scaling of electric and acoustic stimuli was performed in cochlear implant (CI) recipients equipped with Nucleus™ systems in order to achieve a normal loudness perception in the whole dynamic range of acoustic input. For each electrode, the lower and upper limits of electric stimulus were defined by the values corresponding to “very soft” and “too loud”. Within this dynamic range, the stimulus strength intervals associated to the verbal categories “soft”, “medium”, “loud… Expand

Figures and Topics from this paper

Electric and acoustic dynamic ranges and loudness growth functions: a within-subject comparison in cochlear implant patients
TLDR
The dynamic range for electric stimulation by means of acoustic and electric loudness matching and loudness growth as a function of electric stimulus amplitude across the DR is estimated and patterns of variation can be observed. Expand
Adjustments of the amplitude mapping function: Sensitivity of cochlear implant users and effects on subjective preference and speech recognition
TLDR
CI users may benefit from different AMF settings in different listening situations regarding subjective preference and speech perception, especially for speech in quiet. Expand
Frequency-dependent loudness balancing in bimodal cochlear implant users
TLDR
Sub-optimal fittings and mismatches in loudness are possible explanations for the large individual differences seen in listeners using bimodal stimulation. Expand
Output compression in cochlear implants: The added value of subject-specific parameter optimization
A cochlear implant (CI) is an electronic device that can provide a sense of hearing to deaf or profoundly hearing impaired listeners by directly activating auditory nerve fibers. Optimal auditoryExpand
Bimodal Stimulation Towards Binaural Integration
CONCLUSION. In users of a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, frequency-dependent loudness balancing between devices did, on average, not lead to improved speechExpand
Real-time loudness normalisation with combined cochlear implant and hearing aid stimulation
TLDR
The comparison between the original acoustical loudness model and the new simplified model showed loudness differences below 3% for almost all tested speech-like stimuli and levels, and there was no effect of balancing the loudness growth across ears for speech perception ability in quiet and in noise. Expand
Electrically-evoked auditory steady-state responses as neural correlates of loudness growth in cochlear implant users
TLDR
A good correspondence was found between the response amplitude functions and the behavioral loudness growth functions, encouraging for future advances in individual, more automatic, and objective fitting of cochlear implant fitting. Expand
Loudness Functions and Binaural Loudness Summation in Bilateral Cochlear Implant Users
Loudness functions and binaural loudness summation was investigated in acoustically stimulated bilaterally implanted cochlear implant users. The study was aimed at evaluating growth of loudnessExpand
Optimal gain control step sizes for bimodal stimulation
TLDR
The objective was to relate and individualise the step sizes of the loudness controls to obtain a similar perceptual effect in the two ears to relate the controls such that each step results in a similar loudness difference. Expand
Sensitivity to Interaural Level Difference and Loudness Growth with Bilateral Bimodal Stimulation
TLDR
The interaural level difference (ILD) is an important cue for the localization of sound sources and a linear fit of the loudness growth functions on a decibel-versus-microampere scale shows that the slope depends on the subject’s dynamic ranges. Expand
...
1
2
...

References

SHOWING 1-10 OF 32 REFERENCES
Effects of Dynamic Range and Amplitude Mapping on Phoneme Recognition in Nucleus‐22 Cochlear Implant Users
TLDR
Phoneme recognition with a 4‐channel CIS strategy was only mildly affected by large changes in both electric threshold and loudness mapping, and the decrease in performance caused by a reduced electric dynamic range can be compensated by a more expansive power‐law mapping function. Expand
Loudness perception and late auditory evoked potentials in adult cochlear implant users
TLDR
The results show that LAEP can be used for estimation of both hearing thresholds and most comfortable levels and the best correlation was observed for the N1 deflection. Expand
Loudness of simple and complex stimuli in electric hearing.
  • F. Zeng, R. Shannon
  • Mathematics, Medicine
  • The Annals of otology, rhinology & laryngology. Supplement
  • 1995
TLDR
Loudness function depends on stimulus frequency for simple sinusoidal and pulsatile stimuli in cochlear implants and provides a psychophysical basis for the logarithmic amplitude transformation in commonly used speech processors to compress the wide acoustic dynamic range into a narrow electric dynamic range while preserving normal loudness function. Expand
Monaural and Binaural Loudness Measures in Cochlear Implant Users with Contralateral Residual Hearing
TLDR
It is unlikely that standard monaural fitting methods for cochlear implants and hearing aids will result in balanced loudness between the two ears across a reasonably broad range of frequencies and levels, and it is also likely that output levels of both devices will need to be reduced relative to a mon aural fitting to compensate for the binaural summation of loudness in some listeners. Expand
Adaptive fitting of hearing instruments by category loudness scaling (ScalAdapt).
TLDR
An adaptive fitting strategy (ScalAdapt) using category loudness scaling that provides consistently higher objective and subjective benefits (self-assessment inventory) than for instance NAL-based fittings. Expand
[The Würzburg auditory field, a test for prosthetic audiometry].
TLDR
The test called "Das Wurzburger Horfeld" yields primarily prosthetic data, based on the principle of absolute category scaling of loudness and defines an acoustic sensation using the parameters of frequency and intensity. Expand
Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
  • R. Shannon
  • Materials Science, Medicine
  • Hearing Research
  • 1983
TLDR
Measurements from stimulation of a single channel at a time of cochlear implants indicate a central mechanism that is still intact in implant patients, and the shape of the threshold vs. frequency curve can be partially related to the membrane biophysics of the remaining spiral ganglion and/or dendrites. Expand
[Experience with electrostimulation of the acoustic nerve before cochlea implantation].
TLDR
A cross correlational analysis of the data was performed in order to eventually discover redundancies among the different test components, and one of these tests may be eliminated for routine test purposes. Expand
A multi-channel hearing prosthesis for profound-to-total hearing loss.
TLDR
A multi-channel cochlear implant hearing prosthesis providing 22 separate channels of stimulation has been developed and speech perception results indicate that they were able to obtain open-set speech recognition scores for phonetically balanced words, CID sentences and spondees. Expand
Operating ranges and intensity psychophysics for cochlear implants. Implications for speech processing strategies.
TLDR
Psychophysical data suggest that membrane characteristics and other factors impose marked alterations on incoming electrical stimuli, which must be considered carefully when developing speech encoding strategies. Expand
...
1
2
3
4
...