In vitro comparison of Chen medium and Optisol-GS medium for human corneal storage.

@article{Nelson2000InVC,
  title={In vitro comparison of Chen medium and Optisol-GS medium for human corneal storage.},
  author={Lisa R. Nelson and David O. Hodge and William M. Bourne},
  journal={Cornea},
  year={2000},
  volume={19 6},
  pages={
          782-7
        }
}
PURPOSE To compare paired human corneas after storage at 4 degrees C in Chen medium (CM) and Optisol-GS medium (OM) for 7, 10, 14, and 21 days. METHODS One cornea of each pair from nine human donors was randomly stored in either CM or OM, with its mate cornea stored in the other medium. Three pairs of corneas were stored for 7 days and two pairs each were stored for 10, 14, and 21 days at 4 degrees C. Baseline corneal thickness measurements and endothelial photographs were obtained with a… CONTINUE READING

Citations

Publications citing this paper.
SHOWING 1-9 OF 9 CITATIONS

Endothelial Cell Viability of Donor Corneas Preserved in Eusol-C Corneal Storage Medium.

  • Experimental and clinical transplantation : official journal of the Middle East Society for Organ Transplantation
  • 2016