Imaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture

@inproceedings{Gong2017ImagingEO,
  title={Imaging Evaluation of the Safe Region for Distal Locking Screw of Proximal Femoral Nail Anti-Rotation in Patients with Proximal Femoral Fracture},
  author={Jinpeng Gong and Pengcheng Liu and Ming Cai},
  booktitle={Medical science monitor : international medical journal of experimental and clinical research},
  year={2017}
}
BACKGROUND Proximal femoral nail anti-rotation (PFNA) is a standard femoral intertrochanteric fracture operation. Iatrogenic vascular injury, although uncommon, is a reported complication of PFNA surgery as well as a complication of hip fracture surgery. This study aimed to compare the safety and best use of the distal locking screw in 170 mm PFNA and 240 mm PFNA devices, and to determine the safe region for placement of the distal locking screw in PFNA surgery. MATERIAL AND METHODS A… CONTINUE READING