Hypotony after 25-gauge vitrectomy using oblique versus direct cannula insertions in fluid-filled eyes.

@article{Hsu2008HypotonyA2,
  title={Hypotony after 25-gauge vitrectomy using oblique versus direct cannula insertions in fluid-filled eyes.},
  author={Jason Edward Hsu and Eric W. S. Chen and Omesh P Gupta and Mitchell S Fineman and Sunir J. Garg and Carl D. Regillo},
  journal={Retina},
  year={2008},
  volume={28 7},
  pages={937-40}
}
PURPOSE To compare intraocular pressure (IOP) and rates of postoperative hypotony with 25-gauge pars plana vitrectomy (PPV) without tamponade using oblique versus direct cannula insertions. METHODS A prospective consecutive series of eyes that underwent 25-gauge PPV without tamponade using an oblique cannula insertion technique was compared with a historical consecutive series of eyes that underwent 25-gauge PPV without tamponade using direct cannula insertions. IOP was recorded before… CONTINUE READING