Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants.

@article{Rothman1996HydroxyapatitecoatedFS,
  title={Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants.},
  author={Richard H. Rothman and William James Hozack and Anil S. Ranawat and Louise M. Moriarty},
  journal={The Journal of bone and joint surgery. American volume},
  year={1996},
  volume={78 3},
  pages={
          319-24
        }
}
Fifty-two pairs of patients who had had a total hip arthroplasty with a porous-coated femoral implant were studied in a retrospective, matched-pair analysis. Half of the patients had received a femoral component coated with hydroxyapatite and the other half (the controls), an identical component but without hydroxyapatite. The patients were matched for age, sex, weight, diagnosis, Charnley class, operative approach, and duration of follow-up. Identical uncoated hemispherical acetabular implants… CONTINUE READING