High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.

@article{Hallan2006HighWR,
  title={High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.},
  author={Geir Hallan and Stein Atle Lie and Leif Ivar Havelin},
  journal={Acta orthopaedica},
  year={2006},
  volume={77 4},
  pages={575-84}
}
BACKGROUND High wear rates and femoral and acetabular osteolysis have been-and still are-the main problems in uncemented total hip replacement. We reviewed 96 consecutive cementless total hip replacements of 4 different designs. PATIENTS AND METHODS 21 PCA, 25 Harris Galante Porous/Harris Galante I (stem/cup), 25 Profile pressfit/ Tri-Lock Plus (stem/cup) and 25 Profile HA-coated/Tri-Lock Plus (stem/cup) prostheses were included. The operations were performed in the period 1984-1991. Median… CONTINUE READING