High-Energy X-Ray Imaging Applied to Nondestructive Characterization of Large Nuclear Waste Drums

@article{Estre2013HighEnergyXI,
  title={High-Energy X-Ray Imaging Applied to Nondestructive Characterization of Large Nuclear Waste Drums},
  author={Nicolas Estre and Daniel Eck and Jean-Luc Pettier and Emmanuel Payan and Christophe Roure and Eric Simon},
  journal={IEEE Transactions on Nuclear Science},
  year={2013},
  volume={62},
  pages={3104-3109}
}
As part of its R&D programs on non-destructive testing of nuclear waste drums, CEA is commissioning an irradiation cell named CINPHONIE, at Cadarache. This cell allows high-energy imaging (radiography and tomography) on large volumes (up to 5 m3) and heavy weights (up to 5 tons). A demonstrator has been finalized, based on existing components. The X-ray source is a 9 MeV LINAC which produces Bremsstrahlung X-rays (up to 23 Gy/min at 1 meter in the beam axis). The mechanical bench is digitally… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-10 of 12 references

Commissioning of on-site partial CT evaluation by 950 keV and 3.95 MeV X-band linac X-ray sources

  • M. Uesaka
  • Proc. Int. Workshop Breakdown Science and High…
  • 2012
1 Excerpt

Geant4, a simulation toolkit

  • S. Agostinelli
  • Nucl. Instrum. Methods Phys. Res. A, vol. 506, pp…
  • 2003
1 Excerpt

High energy X-ray imagery on large or dense objects: Definition and performance studies of measurement devices by simulation

  • J. L. Pettier
  • Proc. 3rd Int. Conf. Emerging Technologies in NDT…
  • 2003
1 Excerpt

CCD based high energy large field X-ray digital radiographic system

  • M. Antonakios
  • Proc. 15th World Conf. Non-Destructive Testing…
  • 2000
1 Excerpt

Absorption and noise in x-ray phosphors

  • R. Swank
  • J. Appl. Phys., vol. 44, no. 9, p. 287, 1997…
  • 1997
1 Excerpt

Similar Papers