Harmonic Compensation With Zero-Sequence Load Voltage Control in a Speed-Sensorless DFIG-Based Stand-Alone VSCF Generating System

@article{Pattnaik2013HarmonicCW,
  title={Harmonic Compensation With Zero-Sequence Load Voltage Control in a Speed-Sensorless DFIG-Based Stand-Alone VSCF Generating System},
  author={Monalisa Pattnaik and Debaprasad Kastha},
  journal={IEEE Transactions on Industrial Electronics},
  year={2013},
  volume={60},
  pages={5506-5514}
}
Doubly fed induction generator (DFIG)-based stand-alone variable-speed constant-frequency systems reported so far cannot supply nonlinear unbalanced load current containing cophasor components. This paper presents three topologies of a stand-alone DFIG which can handle this type of load. The harmonic/imbalance component of the load current in each case is supplied by the stator-side converter. In the first option, a Δ/Y transformer with neutral connection supplies the load. However, the… CONTINUE READING
Highly Cited
This paper has 17 citations. REVIEW CITATIONS

Citations

Publications citing this paper.
Showing 1-10 of 14 extracted citations

Sensorless direct voltage control for stand-alone DFIG with improved negative-sequence voltage compensation

2014 16th European Conference on Power Electronics and Applications • 2014
View 5 Excerpts
Highly Influenced

Improved Unbalance Compensation for Energy Management in Multi-Microgrid System with Internet of Things Platform

2018 IEEE International Conference on Environment and Electrical Engineering and 2018 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) • 2018
View 1 Excerpt

Control of three-level NPC converters in DFIG based off-grid wind energy conversion systems

IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society • 2015
View 2 Excerpts

References

Publications referenced by this paper.
Showing 1-10 of 25 references

Negative sequence compensation within fundamental positive sequence reference frame for a stiff microgrid generation in a wind power system using slip ring induction machine

T. Bhattacharya, L. Umanand
IET Elect. Power Appl., vol. 3, no. 6, pp. 520–530, Nov. 2009. • 2009
View 4 Excerpts
Highly Influenced

Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems

V.-T. Phan, H.-H. Lee
IET Elect. Power Appl., vol. 5, no. 3, pp. 275–287, Mar. 2011. • 2011
View 2 Excerpts

Stationary frame control scheme for a standalone doubly fed induction generator system with effective harmonic voltages rejection

V.-T. Phan, H.-H. Lee
IET Elect. Power Appl., vol. 5, no. 9, pp. 697–707, Nov. 2011. • 2011

Similar Papers

Loading similar papers…