Gradient high-performance liquid chromatography for the simultaneous determination of chlorogenic acid and baicalin in plasma and its application in the study of pharmacokinetics in rats.

@article{Gao2007GradientHL,
  title={Gradient high-performance liquid chromatography for the simultaneous determination of chlorogenic acid and baicalin in plasma and its application in the study of pharmacokinetics in rats.},
  author={Rong Gao and Qiang Zheng and Tao Gong and Yao Fu and Li Deng and Zhirong Zhang},
  journal={Journal of pharmaceutical and biomedical analysis},
  year={2007},
  volume={43 1},
  pages={335-40}
}
A novel HPLC-UV method was developed for the simultaneous determination of two major active components in Yinhuang injection, chlorogenic acid and baicalin, in rat plasma. Extracted from the plasma samples with methanol-acetonitrile (3:1, v/v), the two compounds were successfully separated using a C18 column with a gradient elution composed of 15 and 54% methanol-acetonitrile (1:1, v/v) in 0.2% (v/v) phosphoric acid water solution (pH 2.0). The flow-rate was set at 1 ml min(-1) and the eluent… CONTINUE READING