Goal-Directed Fluid Management Based on the Pulse Oximeter–Derived Pleth Variability Index Reduces Lactate Levels and Improves Fluid Management
@article{Forget2010GoalDirectedFM, title={Goal-Directed Fluid Management Based on the Pulse Oximeter–Derived Pleth Variability Index Reduces Lactate Levels and Improves Fluid Management}, author={P. Forget and F. Lois and M. de Kock}, journal={Anesthesia & Analgesia}, year={2010}, volume={111}, pages={910–914} }
BACKGROUND:Dynamic variables predict fluid responsiveness and may improve fluid management during surgery. We investigated whether displaying the variability in the pulse oximeter plethysmogram (pleth variability index; PVI) would guide intraoperative fluid management and improve circulation as assessed by lactate levels. METHODS:Eighty-two patients scheduled for major abdominal surgery were randomized into 2 groups to compare intraoperative PVI-directed fluid management (PVI group) versus… Expand
Paper Mentions
Interventional Clinical Trial
This randomized control trial aims to assess if Plethysmographic Variability Index
(PVI)-based therapy improves patient outcome in terms of reduced amount and type of fluid
used… Expand
Conditions | Severe Traumatic Brain Injury |
---|---|
Intervention | Device |
Interventional Clinical Trial
The study is a clinical trial, prospective and randomized of 60 patients of both genders,
aged between 18 and 80 years, underwent major abdominal surgery. This study aims to compare… Expand
Conditions | Anesthesia |
---|---|
Intervention | Device |
Observational Clinical Trial
Correct assessment of a patient's volume status is the most important goal for an
anesthetist. However, most of the variables used for fluid response evaluation are invasive
and… Expand
Conditions | Hypotension, Pleth Variability Index |
---|---|
Intervention | Device |
Interventional Clinical Trial
Intraoperative fluid given according to BMI in group B and according to pulse oximeter-
derived pleth variability index(MASIMO RAINBOW PULSE CO OXIMETRY) in group G. Comparison of… Expand
Conditions | Free Tissue Flaps |
---|---|
Intervention | Other |
193 Citations
Pleth variability index-directed fluid management in abdominal surgery under combined general and epidural anesthesia
- Medicine
- Journal of Clinical Monitoring and Computing
- 2014
- 26
Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial
- Medicine
- BMC Anesthesiology
- 2019
- 6
- PDF
Comparison of conventional fluid management with PVI-based goal-directed fluid management in elective colorectal surgery
- Medicine
- Journal of Clinical Monitoring and Computing
- 2018
- 6
- PDF
Evaluation of pulse pressure variation and pleth variability index to predict fluid responsiveness in mechanically ventilated isoflurane‐anesthetized dogs
- Medicine
- Journal of veterinary emergency and critical care
- 2018
- 9
Impact of goal-directed perioperative fluid management in high-risk surgical procedures: a literature review.
- Medicine
- AANA journal
- 2013
- 11
- PDF
Pleth Variability Index to Predict Fluid Responsiveness in Colorectal Surgery
- Medicine
- Anesthesia and analgesia
- 2011
- 63
Pleth variability index predicts fluid responsiveness in mechanically ventilated adults during general anesthesia for noncardiac surgery.
- Medicine
- Journal of cardiothoracic and vascular anesthesia
- 2014
- 14
References
SHOWING 1-10 OF 13 REFERENCES
Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial
- Medicine
- Critical care
- 2007
- 387
- PDF
Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
- Medicine
- European journal of anaesthesiology
- 2010
- 121
Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
- Medicine
- British journal of anaesthesia
- 2008
- 253
- Highly Influential
- PDF
Arterial Versus Plethysmographic Dynamic Indices to Test Responsiveness for Testing Fluid Administration in Hypotensive Patients: A Clinical Trial
- Medicine
- Anesthesia and analgesia
- 2006
- 135
Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room.
- Medicine
- Anesthesiology
- 2007
- 98
- PDF
Using ventilation-induced plethysmographic variations to optimize patient fluid status
- Medicine
- Current opinion in anaesthesiology
- 2008
- 58
Functional hemodynamic monitoring and dynamic indices of fluid responsiveness.
- Medicine
- Minerva anestesiologica
- 2008
- 97
Poor Agreement between Respiratory Variations in Pulse Oximetry Photoplethysmographic Waveform Amplitude and Pulse Pressure in Intensive Care Unit Patients
- Medicine
- Anesthesiology
- 2008
- 92
- PDF
Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence.
- Medicine
- Chest
- 2002
- 1,131
- PDF
Monitoring of peri‐operative fluid administration by individualized goal‐directed therapy
- Medicine
- Acta anaesthesiologica Scandinavica
- 2007
- 239
- PDF