Gelsomino 1 Assessment of a Continuous Blood Gas Monitoring System in Animals during Circulatory stress. Short Title: Continuous Blood Gas Monitoring
@inproceedings{Gelsomino2010Gelsomino1A, title={Gelsomino 1 Assessment of a Continuous Blood Gas Monitoring System in Animals during Circulatory stress. Short Title: Continuous Blood Gas Monitoring}, author={S. Gelsomino and R. Lorusso and S. Romagnoli and U. Livi and R. Carella and F. Luca and A. Renzulli and G. Bolotin and G. Cicco and J. Maessen and P. Stef{\`a}no and G. Gensini}, year={2010} }
Introduction: The study was aimed to determine the measurement accuracy of The CDI TM blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods: Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Argininevasopressin 4, 8 and 16 IU/h), hemorrhage (–10%, –20%, –35%, and –50% of the theoretical volemia), and volume… CONTINUE READING
Tables from this paper
Tables
References
SHOWING 1-10 OF 38 REFERENCES
Clinical evaluation of a continuous intra-arterial blood gas system in critically ill patients
- Medicine
- Intensive Care Medicine
- 2005
- 10
Continuous intra‐arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: A prospective, criterion standard study
- Medicine
- Critical care medicine
- 1994
- 29
Experiences with continuous intra-arterial blood gas monitoring: precision and drift of a pure optode-system
- Medicine
- Minerva anestesiologica
- 2001
- 25
The effects of continuous blood gas monitoring during cardiopulmonary bypass: a prospective, randomized study--Part I.
- Medicine
- The journal of extra-corporeal technology
- 2000
- 13
- PDF
Continuous Blood Gas Monitoring Using an In-Dwelling Optode Method: Clinical Evaluation of the Neotrend Sensor Using a Luer Stub Adaptor to Access the Umbilical Artery Catheter
- Medicine
- Journal of Perinatology
- 2002
- 12
- PDF
A multiparameter sensor for continuous intra‐arterial blood gas monitoring: A prospective evaluation
- Medicine
- Critical care medicine
- 1994
- 160
Evaluation of the Paratrend 7 intravascular blood gas monitor during cardiac surgery: comparison with the C4000 in-line blood gas monitor during cardiopulmonary bypass.
- Medicine
- Journal of cardiothoracic and vascular anesthesia
- 1995
- 45
The effects of continuous blood gas monitoring during cardiopulmonary bypass: a prospective, randomized study--Part II.
- Medicine
- The journal of extra-corporeal technology
- 2000
- 20
- PDF
Clinical evaluation of a new in-line continuous blood gas monitor.
- Chemistry, Medicine
- The journal of extra-corporeal technology
- 1998
- 20
- PDF
Clinical performance of a blood gas monitor: A prospective, multicenter trial
- Medicine
- Critical care medicine
- 1993
- 76