Gannet: A batch‐processing tool for the quantitative analysis of gamma‐aminobutyric acid–edited MR spectroscopy spectra

@article{Edden2014GannetAB,
  title={Gannet: A batch‐processing tool for the quantitative analysis of gamma‐aminobutyric acid–edited MR spectroscopy spectra},
  author={Richard A. E. Edden and Nicolaas A. J. Puts and Ashley D. Harris and Peter B. Barker and C. John Evans},
  journal={Journal of Magnetic Resonance Imaging},
  year={2014},
  volume={40}
}
The purpose of this study is to describe the Gannet toolkit for the quantitative batch analysis of gamma‐aminobutyric acid (GABA) ‐edited MRS data. 
Impact of frequency drift on gamma‐aminobutyric acid‐edited MR spectroscopy
TLDR
To investigate the quantitative impact of frequency drift on Gamma‐Aminobutyric acid (GABA+)‐edited MRS of the human brain at 3 Tesla (T), frequency drift is analyzed through simulation and physical measurements.
Simultaneous editing of GABA and GSH with Hadamard‐encoded MR spectroscopic imaging
To evaluate the feasibility of simultaneous MR spectroscopic imaging (MRSI) of gamma‐aminobutyric acid (GABA) and glutathione (GSH) in the human brain using Hadamard Encoding and Reconstruction of
Frequency and phase correction of J‐difference edited MR spectra using deep learning
To investigate whether a deep learning‐based (DL) approach can be used for frequency‐and‐phase correction (FPC) of MEGA‐edited MRS data.
Advanced processing and simulation of MRS data using the FID appliance (FID‐A)—An open source, MATLAB‐based toolkit
TLDR
A new toolkit for simulation and processing of magnetic resonance spectroscopy data is introduced, and some of its novel features are demonstrated.
Dual‐volume excitation and parallel reconstruction for J‐difference‐edited MR spectroscopy
To develop J‐difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ‐aminobutyric acid (GABA) or glutathione.
HERMES: Hadamard encoding and reconstruction of MEGA‐edited spectroscopy
TLDR
A novel Hadamard‐encoded spectral editing scheme is investigated and its performance in simultaneously quantifying N‐acetyl aspartate and N‐ acetyl as partyl glutamate at 3 Tesla is evaluated.
FSL‐MRS: An end‐to‐end spectroscopy analysis package
We introduce FSL‐MRS, an end‐to‐end, modular, open‐source MRS analysis toolbox. It provides spectroscopic data conversion, preprocessing, spectral simulation, fitting, quantitation, and visualization.
Simultaneous edited MRS of GABA, glutathione, and ethanol
The aim of this work was to develop simultaneous edited MRS of γ‐aminobutyric acid (GABA), glutathione (GSH), and ethanol (EtOH) using Hadamard encoding and reconstruction of MEGA‐edited spectroscopy
Within‐ and between‐session reproducibility of GABA measurements with MR spectroscopy
The reproducibility of the MEGA‐PRESS (MEshcher‐GArwood Point RESolved Spectroscopy) MR spectroscopy sequence for the measurement of gamma‐ aminobutyric acid (GABA) is addressed, focusing on
Quantification of edited magnetic resonance spectroscopy: a comparative phantom based study of analysis methods
A calibrated series of MRS phantoms is used to compare the performance of common spectroscopy analysis tools in the quantification of GABA-edited spectroscopy data. Varied GABA concentration, and
...
...

References

SHOWING 1-10 OF 43 REFERENCES
J‐difference editing of gamma‐aminobutyric acid (GABA): Simulated and experimental multiplet patterns
TLDR
The aim is to investigate factors that influence the multiplet pattern observed in J‐difference editing of gamma‐aminobutyric acid (GABA) and to establish a causal relationship between these factors and the J-difference pattern.
Subtraction artifacts and frequency (Mis‐)alignment in J‐difference GABA editing
To compare the repeatability of γ‐aminobutyric acid (GABA) measurements using J‐difference editing, before and after spectral realignment—a technique which has previously been demonstrated to improve
High resolution spectroscopic imaging of GABA at 3 Tesla
TLDR
High signal‐to‐noise ratio γ‐aminobutyric acid‐MRSI is possible at 3 T within clinically feasible scan times, and the sequence is also expected to co‐edit homocarnosine and macromolecules, giving a composite γ-aminob Deputy acid+ resonance.
Reproducibility of prefrontal γ‐aminobutyric acid measurements with J‐edited spectroscopy
TLDR
This study validates a reproducible method for the quantification of brain metabolites, and provides information on gray/white matter differences that may be important in the interpretation of results in clinical populations.
A detailed analysis of localized J‐difference GABA editing: theoretical and experimental study at 4 T
TLDR
A detailed analysis of J‐difference editing is provided with estimates of the relative amounts of GABA signal losses due to various mechanisms, and an alternative strategy that reduces signal loss due to the four‐compartment distribution is suggested.
Brain GABA editing without macromolecule contamination
TLDR
A new scheme is proposed to edit the 3.0 ppm GABA resonance without macromolecule contamination using a selective editing pulse, which offers a reduction in experimental time (–33%) and an increase in accuracy.
An NMR Phased Array for Human Cardiac 31P Spectroscopy
A four‐coil phased‐array 31P NMR receiver was designed and tested for human cardiac applications, to determine whether the combination of relatively high signal‐to‐noise ratio (SNR) and large field
A constrained least‐squares approach to the automated quantitation of in vivo 1H magnetic resonance spectroscopy data
TLDR
TARQUIN has been shown to be an accurate and robust algorithm for the analysis of magnetic resonance spectroscopy data making it suitable for use in a clinical setting.
Automatic quantitation of localized in vivo 1H spectra with LCModel
The LCModel method analyzes an in vivo spectrum as a Linear Combination of Model in vitro spectra from individual metabolite solutions. Complete model spectra, rather than individual resonances, are
...
...