Formulation and Bioequivalence of Two Valsartan Tablets After a Single Oral Administration

@inproceedings{Zaid2011FormulationAB,
  title={Formulation and Bioequivalence of Two Valsartan Tablets After a Single Oral Administration},
  author={Abdel Naser Zaid and Rita Cortesi and Aiman Qaddomi and Saed Khammash},
  booktitle={Scientia pharmaceutica},
  year={2011}
}
The aim of this study is to assess the quality of Valzan(®) tablet (160 mg, valsartan immediate release test formulation) by comparing its pharmacokinetic parameters with Diovan(®) tablet (160 mg, valsartan reference formulation). Valzan(®) tablets were prepared according to a dry granulation method (roll compaction). To assess the bioequivalence of Valzan(®) tablets a randomized, two-way, crossover, bioequivalence study was performed in 24 healthy male volunteers. The selected volunteers were… CONTINUE READING

Citations

Publications citing this paper.
SHOWING 1-10 OF 14 CITATIONS

DEVELOPMENT AND EVALUATION OF VALSARTAN ORAL CONTROLLED RELEASE FORMULATIONS

VIEW 4 EXCERPTS
CITES METHODS & BACKGROUND
HIGHLY INFLUENCED

References

Publications referenced by this paper.
SHOWING 1-10 OF 20 REFERENCES

Comparative, crossed, double blind, random study to determine the bioequivalence between two valsartan formulations in tablets and capsules

M Pérez, W Cárdenas, G Ramírez, PV. Restrepo
  • Colomb Med
  • 2006