Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation

@article{Elkholy2015ForcesAM,
  title={Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation},
  author={F. Elkholy and T. Panchaphongsaphak and F. Kilic and Falko Schmidt and B. G. Lapatki},
  journal={Journal of Orofacial Orthopedics / Fortschritte der Kieferorthop{\"a}die},
  year={2015},
  volume={76},
  pages={460-475}
}
ObjectivesAligners made of polyethylene terephthalate glycol (PET-G) were tested in an experimental study for labial and palatal translation of an upper central incisor to quantify the forces and moments thus delivered and to biomechanically evaluate the capability of bodily movement.Materials and methodsUsing a resin model of the upper dentition, tooth 21 was separated and connected to a 3D force/moment (F/M) sensor to record the forces and moments delivered by aligners for labial and palatal… CONTINUE READING

Citations

Publications citing this paper.
SHOWING 1-10 OF 10 CITATIONS

Effect of in vitro aging by water immersion and thermocycling on the mechanical properties of PETG aligner material

Benjamin A. Ihssen, Jan H. Willmann, Amr Nimer, Dieter Drescher
  • Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
  • 2019
VIEW 2 EXCERPTS

Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study

Rosaria Bucci, Roberto Rongo, +4 authors Vincenzo D'Antò
  • Progress in orthodontics
  • 2019
VIEW 1 EXCERPT
CITES BACKGROUND

Computational design and engineering of polymeric orthodontic aligners.

  • International journal for numerical methods in biomedical engineering
  • 2017
VIEW 1 EXCERPT
CITES METHODS

Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: An in-vitro study.

  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • 2017
VIEW 2 EXCERPTS
CITES BACKGROUND & RESULTS

Mechanical load exerted by PET-G aligners during mesial and distal derotation of a mandibular canine

F. Elkholy, B. Mikhaiel, Falko Schmidt, B.G. Lapatki
  • Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
  • 2017
VIEW 2 EXCERPTS
CITES BACKGROUND

References

Publications referenced by this paper.
SHOWING 1-10 OF 32 REFERENCES

Clear-Aligner, An alternative orthodontic appliance

T Kim, B Wilhelmy, J Gaugel H o
  • http://www.andersson-gaugel.de/pdf/SD_Clear-Aligner_klein.pdf. Zugegriffen:
  • 2013
VIEW 4 EXCERPTS
HIGHLY INFLUENTIAL

Locating the center of resistance in individual teeth via two- and three-dimensional radiographic data

  • Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
  • 2013
VIEW 5 EXCERPTS
HIGHLY INFLUENTIAL

Biological basis of orthodontic therapy

WR Proffit
  • Proffit WR, Fields HW, Sarver DM (eds) Contemporary orthodontics. Mosby Elsevier, St. Louis,
  • 2007
VIEW 4 EXCERPTS
HIGHLY INFLUENTIAL

The invisalign system

VIEW 13 EXCERPTS
HIGHLY INFLUENTIAL

Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization.

  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • 2014
VIEW 4 EXCERPTS
HIGHLY INFLUENTIAL

Das Clear-Aigner-Konzept nach Dr.Kim

TW Kim, P Stückrad
  • Kieferorthopädie Nachrichten
  • 2010
VIEW 4 EXCERPTS
HIGHLY INFLUENTIAL

In-vivo von Mises strains during Invisalign treatment.

  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
  • 2010
VIEW 8 EXCERPTS
HIGHLY INFLUENTIAL