• Corpus ID: 16061882

Finite Element Analysis of Cemented Hip Arthroplasty: Influence of Stem Tapers

@inproceedings{Abdullah2010FiniteEA,
  title={Finite Element Analysis of Cemented Hip Arthroplasty: Influence of Stem Tapers},
  author={Abdul Halim Abdullah and Mohd Nawi Mohd Asri and Mohd Shahrudin Mohd Alias and Tardan Giha},
  year={2010}
}
Design of hip prosthesis is believed to be an important factor to minimize the aseptic loosening problems and to encourage long term stability. [] Key Method The taper of the prosthesis were design to be 3° at anterior/posterior, 3° at medial/lateral and 10° from wide lateral to narrow medial. Two different load cases representing walking (toe-off phase) and stair-climbing activities are investigated. Proper stress and strain distribution along the femur will enhance bone growth and keep the femur to…

Figures and Tables from this paper

Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur, and the corresponding stress levels of intact fe...

Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness

The results show that small variations in alignment affect the implant biomechanics, especially around the most proximal and most distal ends of the stem, and suggest that implant position is more influential than cement thickness.

Effects of Prosthesis Stem Materials on Stress Distribution of Total Hip Replacement

Results shows that the largest discrepancy in stress values between intact and THR femur is predicted along the middle region at both lateral and medial planes, and the calculated stress for both THR Femur experienced higher stress magnitude than that of intact femur.

Optimized trapezoidal-shaped hip implant for total hip arthroplasty using finite element analysis

From the findings of this study, it is inferred that profile two shaped stems with the femoral ball size, acetabular cup thickness, and backing cup thickness of 1mm is best suited for the hip replacement.

In vitro assessment of Function Graded (FG) artificial Hip joint stem in terms of bone/cement stresses: 3D Finite Element (FE) study

3D finite element modeling is used for evaluating the artificial hip joint stem that is made of Function Graded (FG) material in terms of joint stress distributions and stem length and showed that the stem length has significant effects on the resultant shear and Von Mises stresses at bone, stem and bone cement for all types of stem materials.

Does the Screw Orientation Effects the Stability of Femoral Neck Fracture?: A Finite Element Analysis

Centrally oriented cannulated screw configuration had the most compression and compression stress on the fracture side, and it had the highest stress values on the implant, which could be a reason for implant failure.

Biomechanical Analysis of Femur with THA and RHA implants using CT-Image Based Finite Element Method

A novel three-dimensional finite element analysis to analyze biomechanical changes in a femur with two different type of hip prosthesis provides an effective method for planning implants that are ideal for patients and for designing future implants that preserves the biomechanics of the femur to maintain its physiology.

Cemented short‐stem total hip arthroplasty: Characteristics of line‐to‐line versus undersized cementing techniques using a validated CT‐based finite element analysis

It is suggested that cemented short stems are a promising solution in osteoporotic bone, and that the line‐to‐line and undersized cementing techniques provide similar outcomes.

Orthopaedic Analysis of Principal Stress Projection in Femur with Total Hip Ar throplasty using CT-image Based Finite Element Method

The research demonstrates a novel three-dimensional finite element analysis to analyze biomechanical changes in a femur with implant, providing an effective method for planning implants that are ideal for patients and for designing future implants that preserves the biomechanics of the femur to maintain its physiology.

Tresca Stress Simulation of Metal-on-Metal Total Hip Arthroplasty during Normal Walking Activity

This investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V) using computational simulations using a 2D axisymmetric finite element model.

References

SHOWING 1-10 OF 14 REFERENCES

Stress and Strain Distribution in Cemented Total Hip Arthroplasty for Walking Load Case

The maximum principal stress of THA femur is lower than that predicted in intact femur at the middle region which leads to stress shielding problems, while higher stress at the bottom region enhance bone thickening and contribute to prosthesis loosening.

Design optimization of cementless femoral hip prostheses using finite element analysis.

  • P. Kowalczyk
  • Engineering
    Journal of biomechanical engineering
  • 2001
An efficient numerical model of the Femur-implant system is presented, including the finite element formulation featuring computation of sensitivity gradients, parametric mesh generator, and a gradient-based optimization scheme.

Loadshift – numerical evaluation of a new design philosophy for uncemented hip prosthesis

Hip prostheses alter the load transfer and stress state within the treated femur. This can lead to stress shielding in the proximal femur and subsequent overloading of the diaphysis. We hypothesized

The Influence of Clinical Factors on Periprosthetic Bone Remodeling

The femurs of 11 patients with well-functioning unilateral hip replacements were retrieved at autopsy and analyzed for periprosthetic bone remodeling by dual energy xray absorptiometry; only the bone mineral content of the contralateral femur had a strong predictive value.

The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.

Evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem and found no substantial differences were found in the size and distribution of micromovesment on either interface with respect to the stiffness of the stem.

Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990.

A prospective, national multi-center study of all reoperations after total hip replacement (THR) was started by the Swedish Orthopedic Association in 1979, demonstrating that the average orthopedic surgeon cannot match the results achieved by experts.

Duration and frequency of every day activities in total hip patients.

The elastic modulus for bone.

Finite Element Analysis of the Effects of Stem Geometry, Surface Finish and Cement Viscoelasticity on Debonding and Subsidence of Total Hip Prosthesis

  • Finite Element Analysis of the Effects of Stem Geometry, Surface Finish and Cement Viscoelasticity on Debonding and Subsidence of Total Hip Prosthesis
  • 2001