Fast Unbalanced Three-phase Adjustment Base on Single-phase Load Switching

@article{Zheng2013FastUT,
  title={Fast Unbalanced Three-phase Adjustment Base on Single-phase Load Switching},
  author={Yanwei Zheng and Lisheng Zou and J. He and Yongyi Su and Zhiquan Feng},
  journal={Indonesian Journal of Electrical Engineering and Computer Science},
  year={2013},
  volume={11},
  pages={4327-4334}
}
To balance three-phase loads in distribution network with abundant of single-phase loads, a new wiring method and three-phase loads adjustment policy was proposed in this paper. In the wiring method, a single-phase load was connected with phase A, B and C of trunk line by a controller. When the load of trunk line was unbalanced, the controller will switch the connected single-phase loads from one phase to another to balance it. The minimum count of loads adjustment algorithm and the most… Expand

Figures and Tables from this paper

CURRENT BALANCING FOR DISTRIBUTED SINGLE PHASE LOADS BASED ON AUTOMATED PHASE TRACING
The information of a distributed single-phase loads was used to balance the currents in a three-phase system. The feeder phase and load profile of each single-phase load are used to reconfigure theExpand
Online Centralized Coordination of Charging and Phase Switching of PEVs in Unbalanced LV Networks With High PV Penetrations
TLDR
This article investigates the capability of dynamic PEV load transfer within the three phases of a distribution network to propose a new hybrid PEV coordination approach and performs local voltage profiles improvement by switching PEV at selected single-phase residential houses such that a PEV can be switched from a heavily loaded phase to a (relatively) lightly loaded phase. Expand
Optimal Phase Load Balancing in Low Voltage Distribution Networks Using a Smart Meter Data-Based Algorithm
TLDR
The proposed phase load balancing algorithm led to the following technical effects: decrease of the average current in the neutral conductor and the energy losses with 94%, and increase of the minimum value of the phase voltage at the farthest pillar with 7.14%, compared to the unbalanced case. Expand
Wireless Control System for Three Phase Loads Balancing in Distribution Networks
TLDR
A wireless control system for three phase loads balancing in a regional transformer to solve the problems of the loads imbalance to avoid the losses of the electricity in the distribution networks and also to protect the elements of the network like transformers from damages. Expand
Dynamic Load Balancing and Reactive Power Compensation Switch Embedded in Power Meters
This brief proposes a dynamic intelligent load balancing and reactive power compensation switch plugin for power meters and a smart scalable system architecture applicable as an add-on to theExpand

References

SHOWING 1-10 OF 33 REFERENCES
The Research of Unbalanced Three-Phase Adjustment in Distribution Network
To balance three-phase loads in distribution network with abundant of single-phase loads, the idea of three-phase adjustment and wiring method is proposed in this paper. Three-phase adjustmentExpand
Balancing Compensation of Three-phase Unbalanced Load with Single Phase STATCOM
Due to the low output current harmonic and fast response characteristics,single phase STATCOM is suitable for balancing compensation of three phase unbalanced load.Two kinds of main circuitExpand
Research on Unbalanced Three-phase Power Flow Calculation Method in Islanding Micro Grid
This paper presented a new method for unbalanced three-phase power flow calculation in islanding micro grid.No balance node was set,while the auto power adjusting of each DGR,the static P-f and V-QExpand
Design of Reactive Power Compensation Device in Medium-Low Voltage Unbalanced Distribution Networks
In the medium-low voltage distribution networks,the inductive load and the load imbalance cause great loss of power and low power factor problem.Traditional compensation devices are only applicableExpand
Calculation of Three-Phase Unbalanced Power Flow in Distribution Network Containing Distributed Generation
According to actual conditions of three-phase unbalance in distribution network, to accurately calculate the power flow of distribution network connected with various distributed generations (DG) aExpand
Theoretical line loss calculation with three-phase unbalance degree for low-voltage distribution network
The mean-square-root current method is proposed to calculate the theoretical line loss for low-voltage distribution network.Based on the analysis of three-phase unbalanced line loss,the relationshipExpand
Calculation Method of three-phase Unbalance Factor Based on Load Power
A practical method for the calculation of unbalance factor caused by asymmetric loads in a three-phase three-wire distribution system was presented.By introducing the term of sequence capacity of anExpand
Hybrid Series Compensation Scheme Using Single-phase SSSC
Three-phase unbalanced system will reduce the mechanical and electrical energy interaction,and thus to some extent inhibit SSO.Based on this principle,a compensation method using single-phase SSSC isExpand
Research on Reactive Compensation Method for Unbalanced Load
In view of the hazards caused by three-phase unbalanced load,combined with the actual placement of the capacitor,using programming idea,the paper presents a new compensation algorithm for three-phaseExpand
Research on All-capacitor Adjusted Compensation for Low Voltage Three-phase Unbalance Distribution Network
Measures not only to adjust the three-phase unbalance in low voltage distribution network,but also to solve reactive compensation are researched.Traditional low-voltage compensation device using aExpand
...
1
2
3
4
...