Failure analysis of fractured dental zirconia implants.

@article{Gahlert2012FailureAO,
  title={Failure analysis of fractured dental zirconia implants.},
  author={Michael Gahlert and Doris Burtscher and Ingrid Grunert and Heinz Kniha and Erwin Steinhauser},
  journal={Clinical oral implants research},
  year={2012},
  volume={23 3},
  pages={
          287-93
        }
}
OBJECTIVES The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. METHODS Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient… CONTINUE READING