Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole

@article{GirishKumar2008FabricationOP,
  title={Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole},
  author={Krishnapillai Girish Kumar and Pearl Augustine and Sareena John and Jerzi Radecki and Hanna Radecka},
  journal={Analytical Letters},
  year={2008},
  volume={41},
  pages={1144 - 1157}
}
Abstract The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8 mV/decade and 55.2 mV/decade for PVC membrane and carbon paste sensors respectively over a… Expand
Novel potentiometric sensors for the selective determination of domperidone
The fabrication and electrochemical response characteristics of two novel potentiometric sensors for the selective determination of domperidone (DOM) are described. The two fabricated sensorsExpand
Electrochemical sensor for the determination of ketoconazole based on gold nanoparticles modified carbon paste electrode
Abstract The present research work is devoted to a carbon paste electrode modified with gold nanoparticles for the detection of low concentration of ketoconazole (KCZ). A simple preparation procedureExpand
Electrochemical Reduction and Voltammetric Determination of Metronidazole Benzoate at Modified Carbon Paste Electrode
Abstract A metalloporphyrin incorporated carbon paste sensor has been developed for the determination of metronidazole benzoate (MTZB). Zn(II) complex of 5,10,15,20-tetrakis (3-methoxy-4-hydroxyExpand
Voltammetric determination of sulfamethoxazole at a multiwalled carbon nanotube modified glassy carbon sensor and its application studies.
TLDR
The voltammetric analysis of SMX at a multiwalled carbon nanotube (MWCNT)-Nafion modified glassy carbon electrode (GCE) showed good stability, selectivity and was successfully used to quantify SMX in pharmaceutical formulations and urine sample. Expand
Voltammetric study of pyridine-2-aldoxime methochloride at poly(p-toluene sulfonic acid) modified glassy carbon sensor and its analytical applications
A poly(p-toluene sulfonic acid) (p-TSA) modified glassy carbon electrode (GCE) was fabricated by electropolymerisation using cyclic voltammetry (CV). This chemically modified electrode showed highExpand
Differential pulse voltammetric determination and catalytic oxidation of sulfamethoxazole using [5,10,15,20- tetrakis (3-methoxy-4-hydroxy phenyl) porphyrinato] Cu (II) modified carbon paste sensor.
TLDR
A metalloporphyrin modified carbon paste sensor was fabricated and the electrochemical behaviour of SM was studied using differential pulse voltammetry (DPV) and it was found that under optimum conditions the oxidation peak current was linear to the concentration of SM. Expand
Nanomaterials for Pharmaceuticals Determination
Nanomaterials play an important role in the fabrication of many devices and modified materials, due to their unique properties, such as a large surface area/volume ratio and their high mechanicalExpand
Determination of Ketoconazole in Pharmaceutical Formulations
Ketoconazole is used to treat fungal infections. Ketoconazole is most often used to treat fungal infections that can spread to different parts of the body through the bloodstream such as yeastExpand

References

SHOWING 1-10 OF 41 REFERENCES
A Novel Potentiometric Sensor for the Determination of Nimesulide
A novel electrochemical sensor has been developed for the determination of nimesulide. The sensor is based on the NIM- molybdophosphoric acid (MPA) as the electroactive material in PVC matrix inExpand
A PVC plasticized membrane sensor for nickel ions
Abstract.A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited byExpand
Mebendazole selective membrane sensor and its application to pharmaceutical analysis.
TLDR
A PVC membrane sensor for the selective determination of mebendazole (MBZ) was fabricated and showed a very good selectivity for MBZ with respect to a large number of ions. Expand
Chemically modified carbon paste electrode for the potentiometric determination of dicylomine hydrochloride in batch and in FIA conditions.
TLDR
The electrode applied to the potentiometric determination of dicylominium ion in its pure state and in pharmaceutical preparations in batch and flow injection conditions and in biological fluids using standard additions method exhibits good selectivity for DcCl with respect to a large number of inorganic cations, sugars, amino acids and organic substances of biological fluids. Expand
Electrochemical Determination of Terazosin in Pure Form and in Dosage Forms
Two methods have been developed for the determination of terazosin in pure form and in dosage forms- one based on a potentiometric sensor and the other a voltammetric technique.Expand
Stripping voltammetric and polarographic techniques for the determination of anti-fungal ketoconazole on the mercury electrode.
TLDR
Two procedures, based on differential pulse polarography (DPP) and AdS-DPV in aqueous medium were developed for the determination of ketoconazole in a gel formulation and spiked urine samples, respectively, showed that the reduction of ketconazole is irreversible and the limiting current is adsorption controlled. Expand
PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood and soil using tetrazolium pentachlorophenolate.
TLDR
The electrode has been utilized as an end point indicator electrode for the determination of PCP using potentiometric titration and gave results that compare favorably with those obtained by gas chromatography. Expand
Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations.
TLDR
The CP electrode has been utilized as an end point indicator electrode in potentiometric titration of some anions, and applied for the determination of anionic surfactants in some commercial detergents and waste water. Expand
Potentiometric Cd2+-selective electrode with a detection limit in the low ppt range
Abstract A recently introduced model describing the response curves of polymer membrane ion-selective electrodes (ISEs) is used here to optimize a Cd 2+ -ISE with a view to achieve very low detectionExpand
Membrane electrodes for the determination of glutathione.
TLDR
Determination of GSH in capsules by the proposed electrodes revealed their applicability for determination of G SH in its pharmaceutical formulations and they were used to determine GSH selectively in presence of its oxidized form (GSSG). Expand
...
1
2
3
4
5
...